Skip to main content
ABB 1SDA068081R1 — MCCB up to 100A

ABB 1SDA068081R1 XT4N 160 TMD 25-300 3p F F, 25 A

MPN1SDA068081R1

ABB XT4N 160 TMD 25-300 3p F F distribution circuit breaker, 25 A rated current (In), 160 A frame (Iu), 690 V, 3-pole, thermal-magnetic trip unit.

$375.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

1SDA068081R1 — Electrical
ParameterValue
Rated current (In)25 A
Number of poles3 poles
Rated voltage (Ur)690 V
Rated uninterrupted current (Iu)160
Rated frequency50 / 60 Hz
1SDA068081R1 — Protection
ParameterValue
Trip unitTMD
1SDA068081R1 — Mechanical
ParameterValue
Dimensions (L x W x H)8.25cm x 10.5cm x 16cm
Weight2.1 Kg
1SDA068081R1 — Identification
ParameterValue
Type designationXT4N 160 TMD 25-300 3p F F
Product type designationXT4N 160 TMD 25-300 3p F F Distribution Circuit Breakers
SizeXT4
1SDA068081R1 — Other specifications
ParameterValue
In25

Product details

Frame and trip unit — what In and Iu mean for the BOM line

The 1SDA068081R1 is an ABB XT4N 160 TMD 25-300 3p F F distribution circuit breaker. The 'In' rating of 25 A is the continuous current the breaker carries without tripping — it sets the overload threshold for the protected circuit. The 'Iu' of 160 A is the frame rating, meaning the XT4 chassis and contacts are rated for 160 A thermal current; the installed trip unit limits the actual protection to 25 A. The TMD trip unit is thermal-magnetic: the thermal element handles overload protection (inverse-time curve), and the magnetic element provides instantaneous short-circuit response. The adjustable range 25-300 refers to the thermal-magnetic setting range in A — this unit is fixed at 25 A, not field-adjustable.

Electrical ratings and panel fit

Rated voltage is 690 V AC, 50/60 Hz, covering standard low-voltage distribution networks up to 690 V line-to-line. Three-pole construction handles three-phase circuits. Dimensions 8.25 cm x 10.5 cm x 16 cm (LxWxH) — confirm DIN-rail or mounting plate space; the XT4 frame is a common ABB molded-case size.

Frequently asked questions

What do In 25 A and Iu 160 A mean on this breaker?

In 25 A is the continuous current rating — the breaker will carry 25 A indefinitely without tripping. Iu 160 A is the frame rating, indicating the XT4 chassis is designed for up to 160 A thermal current; the installed TMD trip unit limits protection to 25 A.

MPN
1SDA068081R1