ABB 1SDA068112R1 — MCCB up to 100A

ABB 1SDA068112R1 XT4N 160 MA 10 Motor Protection Circuit Bre

MPN1SDA068112R1

ABB 1SDA068112R1, XT4N 160 MA 10 motor protection circuit breaker, 3-pole, In 10 A, Iu 160 A frame, adjustable magnetic-only trip, 690 V, 50/60 Hz.

$433.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

1SDA068112R1 — Electrical
ParameterValue
Rated current (In)10 A
Number of poles3 poles
Rated voltage (Ur)690 V
Rated uninterrupted current (Iu)160
Rated frequency50 / 60 Hz
1SDA068112R1 — Protection
ParameterValue
Trip unitMA
1SDA068112R1 — Mechanical
ParameterValue
Dimensions (L x W x H)8.25cm x 10.5cm x 16cm
Weight2.1 Kg
1SDA068112R1 — Identification
ParameterValue
Type designationXT4N 160 MA 10 Im=50...100 3p F F
Product type designationMotor Protection Circuit Breakers
SizeXT4
1SDA068112R1 — Other specifications
ParameterValue
In10

Product details

Motor protection for the grease-and-grit route

The ABB 1SDA068112R1 is an XT4N 160 frame motor protection circuit breaker with a magnetic-only (MA) trip unit, set for 10 A full-load current. The adjustable instantaneous magnetic trip range (Im) goes from 50 to 100 A, so it handles motor inrush without nuisance tripping on start-up. Rated for 690 V at 50/60 Hz, this is a three-pole unit built for protecting induction motors in industrial environments — think pumps, conveyors, and fans out on the plant floor where heat, dust, and vibration are the real test.

The 160 A frame rating (Iu) means the physical breaker shell and contacts are sized for a 160 A maximum; you're using a small chunk of that capacity here, which gives thermal headroom in the enclosure. The MA trip unit means no thermal overload — it's strictly magnetic (short-circuit and start-up protection), so you must pair this breaker with a separate overload relay for running protection. The adjustable Im range (50 to 100 A) lets you dial in the magnetic pickup to ride through your motor's locked-rotor current without tripping, typically set at 8-12x the motor FLA for standard induction motors.

Frequently asked questions

What does the MA trip unit mean for application?

The MA trip unit is magnetic-only — it provides short-circuit and instantaneous overcurrent protection but no thermal overload. You must pair this breaker with a separate thermal overload relay (e.g., ABB TA or TF series) to protect the motor from running overloads.

What is the adjustable magnetic release range?

The adjustable instantaneous magnetic release (Im) ranges from 50 to 100 A, allowing you to set the short-circuit pickup level to suit the motor's starting inrush without nuisance tripping.

What voltage and frequency is this breaker rated for?

Rated voltage is 690 V AC, and it handles both 50 and 60 Hz supplies.