ABB 1SDA068118R1 — MCCB up to 100A

ABB 1SDA068118R1 XT4N MCCB, 100 A, Motor Protection

MPN1SDA068118R1

ABB XT4N 160 MA 100 MCCB, 3-pole, In 100 A, Iu 160 A, magnetic-only trip unit, 50/60 Hz, 690 V.

$433.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

1SDA068118R1 — Electrical
ParameterValue
Rated current (In)100 A
Number of poles3 poles
Rated voltage (Ur)690 V
Rated uninterrupted current (Iu)160
Rated frequency50 / 60 Hz
1SDA068118R1 — Protection
ParameterValue
Trip unitMA
1SDA068118R1 — Mechanical
ParameterValue
Dimensions (L x W x H)8.25cm x 10.5cm x 16cm
Weight2.1 Kg
1SDA068118R1 — Identification
ParameterValue
Type designationXT4N 160 MA 100 Im=500...1000 3p F F
Product type designationMotor Protection Circuit Breakers
SizeXT4
1SDA068118R1 — Other specifications
ParameterValue
In100

Product details

Motor protection breaker with magnetic-only trip

The ABB 1SDA068118R1 is an XT4N frame MCCB with a magnetic-only (MA) trip unit, rated In=100 A continuous current on a Iu=160 A frame. This means the breaker provides short-circuit and magnetic protection only — there is no thermal overload element, so it relies on an upstream or external overload relay for motor running protection. The type code XT4N 160 MA 100 Im=500...1000 3p F F confirms the adjustable instantaneous trip range: 500 to 1000 A (5–10× In), which is the setting range for coordinating with motor inrush. Rated voltage is 690 V AC, covering 400 V and 480 V systems with headroom for 600 V class. The 3-pole configuration is standard for three-phase motor circuits. Frequency rating is 50/60 Hz, suitable for global installations.

Sizing and coordination for motor branch circuits

The 100 A rated current matches motor FLA up to about 100 A, but the magnetic-only trip means the breaker does not carry the overload function — pair it with a separate thermal overload relay or motor protection relay upstream. The adjustable instantaneous trip (Im=500–1000 A) lets you set the magnetic pickup above motor starting current to avoid nuisance trips on inrush, while still clearing a bolted fault. Frame size XT4N supports the 160 A continuous rating of the frame itself, so the breaker can be re-fitted with a higher-rated trip unit later if the motor load changes, without swapping the entire breaker. Dimensions are 8.25 cm wide × 10.5 cm deep × 16 cm high, fitting standard panel layouts for MCCB up to 100 A class.

Frequently asked questions

What does the MA trip unit mean on this MCCB?

MA stands for magnetic-only — the breaker provides short-circuit and magnetic protection with an adjustable instantaneous trip range of 500–1000 A (Im=500...1000). It does not include a thermal overload element, so an external overload relay is required for motor running protection.

What is the rated current In and frame rating Iu of 1SDA068118R1?

Rated current In is 100 A, installed on a frame rated Iu=160 A. The frame can accept a higher-rated trip unit up to 160 A if needed.