ABB 1SDA068129R1 — Molded Case Circuit Breakers (MCCB)

ABB 1SDA068129R1 XT4N 160 Ekip I MCCB, 100 A, 3-Pole

MPN1SDA068129R1

ABB XT4N 160 Ekip I MCCB, 3-pole, In=100 A, Iu=160 A, 690 V, 50/60 Hz, distribution circuit breaker.

$456.00Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

1SDA068129R1 — Ratings
ParameterValue
Number of poles3 poles
1SDA068129R1 — Other specifications
ParameterValue
In100
Iu160
DimensionsXT4
TypeXT4N 160 Ekip I In=100A 3p F F
Weight2.1 Kg
Trip unitsEkip I
Product typeDistribution Circuit Breakers
Dimensions (LxWxH)8.25cm x 10.5cm x 16cm
Current100 A
Voltage690 V
Rated frequency50 / 60 Hz

Product details

Rated current and frame sizing for panel coordination

The 1SDA068129R1: Rated current In=100 A sets the continuous load the breaker carries without tripping in a 40 °C ambient — match this to the downstream conductor ampacity and the load current on the distribution bus. The Iu=160 A frame rating means the XT4 mechanical shell and contacts are sized for 160 A thermal withstand, giving 60 A of headroom above the In setting. This headroom supports selective coordination with upstream breakers — the XT4 can ride through short-time overcurrents without opening before the downstream device clears. Three-pole configuration covers three-phase distribution circuits —, L2, L3. The neutral is handled separately or via a 4-pole variant if needed.

Ekip I trip unit — LI protection curve

The Ekip I electronic trip unit provides LI protection — long-time delay (L) for overloads and instantaneous (I) for short-circuits. No ground-fault or short-time delay function; this is a straight distribution breaker, not a main or generator breaker. Rated voltage 690 V AC at 50/60 Hz covers 400 V and 480 V systems with margin — the breaker interrupts at the full rated voltage without derating for the standard distribution voltages.

Lifecycle and sourcing — active production

The XT4 platform is ABB's current-generation molded-case breaker family, replacing the older Tmax T4 series. The Ekip I trip unit is the electronic entry-level option — field-replaceable and compatible with the XT4 accessories (auxiliary contacts, shunt trip, motor operator).

Frequently asked questions

What is the difference between In=100 A and Iu=160 A on this breaker?

In=100 A is the rated continuous current the breaker is set to carry without tripping. Iu=160 A is the maximum frame rating — the breaker's mechanical and thermal capacity. The 60 A difference provides headroom for short-time thermal withstand and selective coordination with downstream breakers.

What trip unit does 1SDA068129R1 use?

It uses the Ekip I electronic trip unit providing LI protection — long-time delay for overloads and instantaneous for short-circuits. No ground-fault or short-time delay functions.