ABB 1SDA068150R1 — MCCB up to 100A

ABB 1SDA068150R1 XT4N MCCB, 100A, 4-Pole, Ekip I Trip Unit

MPN1SDA068150R1

ABB XT4N 160 Ekip I MCCB, 4-pole, In=100A, Iu=160A, 690V AC, 50/60 Hz, electronic trip unit.

$591.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

1SDA068150R1 — Electrical
ParameterValue
Rated current (In)100 A
Number of poles4 poles
Rated voltage (Ur)690 V
Rated uninterrupted current (Iu)160
Rated frequency50 / 60 Hz
1SDA068150R1 — Protection
ParameterValue
Trip unitEkip I
1SDA068150R1 — Mechanical
ParameterValue
Dimensions (L x W x H)8.25cm x 14cm x 16cm
Weight3.1 Kg
1SDA068150R1 — Identification
ParameterValue
Type designationXT4N 160 Ekip I In=100A 4p F F
Product type designationDistribution Circuit Breakers
SizeXT4
1SDA068150R1 — Other specifications
ParameterValue
In100

Product details

Frame Rating vs Continuous Current — Selectivity Headroom

The 1SDA068150R1: The XT4N 160 frame (Iu=160 A) carries a fitted Ekip I electronic trip unit set to In=100 A. This 60 A gap between the frame rating and the trip setting gives the coordination engineer headroom for selective coordination downstream — the breaker can pass a short-time withstand current up to the frame limit without tripping, letting a downstream device clear the fault first. Rated voltage is 690 V AC at 50/60 Hz, covering standard industrial distribution voltages from 400 V to 690 V line-to-line without derating the frame.

4-Pole Configuration for Neutral Protection

Four poles mean the neutral pole is switched and protected — required in TN-S or TN-C-S systems where the neutral is distributed through the breaker and must be isolated during maintenance. The XT4N footprint (8.25 cm x 14 cm x 16 cm) fits standard ABB switchboard mounting plates without adaptor brackets.

Lifecycle and Sourcing — Active Production

No official successor or cross-reference exists because the part is the current offering. If the BOM calls for a different trip rating, the XT4N family supports interchangeable Ekip trip units without changing the breaker frame.

Frequently asked questions

What is the difference between In=100 A and Iu=160 A on this breaker?

In=100 A is the continuous current rating set by the Ekip I trip unit — the breaker will carry 100 A indefinitely without tripping. Iu=160 A is the maximum current the XT4N frame can handle thermally; the 60 A margin allows the breaker to pass short-time fault currents up to the frame limit for selective coordination with downstream devices.