PST30-600-70 Softstarter - 30 A - Main Circuit 208... 600 V AC

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

1SFA894002R7000 key specifications
ParameterValue
Terminal typeScrew Terminals
Product main typePST30
VoltageMain Circuit 208 ... 600 V AC
Initial voltage during start30 ... 70 %
Step down voltage special ramp100 ... 30 %
Rated control supply voltage100 ... 250 V AC
Rated control circuit voltageDC Operation 24 V
Current limit function1.5 ... 7xIe
Starting capacity at maximum rated current ie3xIe for 15s
Rated operational current - In-Line connection30 A
Rated operational current - inside delta connection52 A
Rated operational power - In-Line connection(400 V) 15 kW

All specifications

1SFA894002R7000 additional specifications
ParameterValue
Rated operational power - inside delta connectionat 400 V 25 kW
Rated frequency50/60 Hz
IP ratingacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
ProtocolFiledBusPlug(Standard)
Switch for inside delta connectionYes
Material compliance (Conflict minerals reporting template)9AKK108467A5658
Ramp time0 ... 120 second [unit of time]
Analog outputs0...10 volts
Run signal relayYes
Tightening torqueControl Circuit 0.5 N·m
Fault signal relayYes
Overload protectionBuild-in electronic overload protection
By-pass signal relayYes
Overload signal relayYes
Ambient air temperatureOperation 0 ... +50 °C
Service factor percentage115 %
Object classification codeQ
Signal indication faultRed
Integrated electronic overloadYes
Connecting capacity main circuitRigid 1 x 10 ... 95 mm²
Connecting capacity supply circuitRigid 1 x 2.5
Signal indication protectionYellow
Connecting capacity control circuitRigid 1 x 2.5 mm²
Popular downloads (Instructions and manuals)1SFC132003M0201
Popular downloads (Data sheet, technical information)1SFC132005C0201

Frequently asked questions

What is the replacement for 1SFA894002R7000?

Buyers need to find a current alternative for an obsolete part.

Is the ABB 1SFA894002R7000 softstarter obsolete?

Determines if the part is still available and supported.

Where can I buy 1SFA894002R7000 in stock?

Sourcing buyers need immediate availability for BOM fulfillment.

What is the price of 1SFA894002R7000?

Budgeting and cost comparison for procurement.

What are the specifications of 1SFA894002R7000 PST30-600-70?

Design engineers need to validate fit and function.

Does 1SFA894002R7000 have built-in overload protection?

Critical for application safety and motor protection.

MPN
1SFA894002R7000