1SFA894002R7000 - ABB
MPN1SFA894002R7000
Obsolete
PST30-600-70 Softstarter - 30 A - Main Circuit 208... 600 V AC
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
Specifications
| Parameter | Value |
|---|---|
| Terminal type | Screw Terminals |
| Product main type | PST30 |
| Voltage | Main Circuit 208 ... 600 V AC |
| Initial voltage during start | 30 ... 70 % |
| Step down voltage special ramp | 100 ... 30 % |
| Rated control supply voltage | 100 ... 250 V AC |
| Rated control circuit voltage | DC Operation 24 V |
| Current limit function | 1.5 ... 7xIe |
| Starting capacity at maximum rated current ie | 3xIe for 15s |
| Rated operational current - In-Line connection | 30 A |
| Rated operational current - inside delta connection | 52 A |
| Rated operational power - In-Line connection | (400 V) 15 kW |
All specifications
| Parameter | Value |
|---|---|
| Rated operational power - inside delta connection | at 400 V 25 kW |
| Rated frequency | 50/60 Hz |
| IP rating | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
| Protocol | FiledBusPlug(Standard) |
| Switch for inside delta connection | Yes |
| Material compliance (Conflict minerals reporting template) | 9AKK108467A5658 |
| Ramp time | 0 ... 120 second [unit of time] |
| Analog outputs | 0...10 volts |
| Run signal relay | Yes |
| Tightening torque | Control Circuit 0.5 N·m |
| Fault signal relay | Yes |
| Overload protection | Build-in electronic overload protection |
| By-pass signal relay | Yes |
| Overload signal relay | Yes |
| Ambient air temperature | Operation 0 ... +50 °C |
| Service factor percentage | 115 % |
| Object classification code | Q |
| Signal indication fault | Red |
| Integrated electronic overload | Yes |
| Connecting capacity main circuit | Rigid 1 x 10 ... 95 mm² |
| Connecting capacity supply circuit | Rigid 1 x 2.5 |
| Signal indication protection | Yellow |
| Connecting capacity control circuit | Rigid 1 x 2.5 mm² |
| Popular downloads (Instructions and manuals) | 1SFC132003M0201 |
| Popular downloads (Data sheet, technical information) | 1SFC132005C0201 |
Frequently asked questions
What is the replacement for 1SFA894002R7000?
Buyers need to find a current alternative for an obsolete part.
Is the ABB 1SFA894002R7000 softstarter obsolete?
Determines if the part is still available and supported.
Where can I buy 1SFA894002R7000 in stock?
Sourcing buyers need immediate availability for BOM fulfillment.
What is the price of 1SFA894002R7000?
Budgeting and cost comparison for procurement.
What are the specifications of 1SFA894002R7000 PST30-600-70?
Design engineers need to validate fit and function.
Does 1SFA894002R7000 have built-in overload protection?
Critical for application safety and motor protection.
MPN
1SFA894002R7000