The 1SFA894003R7000: The 37 A in-line rating governs the standard motor connection — sized for a 18.5 kW motor at 400 V. The 64 A inside-delta rating applies when the starter is wired in the delta legs of a star-delta motor, boosting capacity to 30 kW at 400 V. The 115 % service factor means the starter can run at 115 % of rated current continuously without tripping, useful for high-inertia loads that need a longer acceleration profile. Control supply accepts 100–250 V AC, with a separate 24 V DC control circuit for the logic inputs. The built-in electronic overload eliminates the need for a separate overload relay, saving a DIN-rail slot. Screw terminals on the control circuit accept 1 × 2.5 mm² rigid; main circuit terminals accept 1 × 10–95 mm² rigid, torqued to 0.5 N·m on the control side. Four signal relays — run, fault, bypass, and overload — give the PLC or DCS discrete feedback for each state. The analog output provides a 0–10 V signal proportional to motor current, useful for trending or HMI display. Communication is via the standard FieldBusPlug, meaning an optional fieldbus adapter module plugs in for PROFIBUS, DeviceNet, or Modbus RTU — no separate gateway needed.
ABB PST37 1SFA894003R7000 Softstarter, 37 A In-Line, 18.5 kW
ABB PST37 series softstarter, order code 1SFA894003R7000, 37 A rated operational current in-line connection, 18.5 kW at 400 V, 100–250 V AC control supply, screw terminals.
Specifications
| Parameter | Value |
|---|---|
| Terminal type | Screw Terminals |
| Product main type | PST37 |
| Voltage | Main Circuit 208 ... 600 V AC |
| Initial voltage during start | 30 ... 70 % |
| Step down voltage special ramp | 100 ... 30 % |
| Rated control supply voltage | 100 ... 250 V AC |
| Rated control circuit voltage | DC Operation 24 V |
| Current limit function | 1.5 ... 7xIe |
| Starting capacity at maximum rated current ie | 3xIe for 15s |
| Rated operational current - In-Line connection | 37 A |
| Rated operational current - inside delta connection | 64 A |
| Rated operational power - In-Line connection | (400 V) 18.5 kW |
All specifications
| Parameter | Value |
|---|---|
| Rated operational power - inside delta connection | at 400 V 30 kW |
| Rated frequency | 50/60 Hz |
| IP rating | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
| Protocol | FiledBusPlug(Standard) |
| Switch for inside delta connection | Yes |
| Material compliance (Conflict minerals reporting template) | 9AKK108467A5658 |
| Ramp time | 0 ... 120 second [unit of time] |
| Analog outputs | 0...10 volts |
| Run signal relay | Yes |
| Tightening torque | Control Circuit 0.5 N·m |
| Fault signal relay | Yes |
| Overload protection | Build-in electronic overload protection |
| By-pass signal relay | Yes |
| Overload signal relay | Yes |
| Ambient air temperature | Operation 0 ... +50 °C |
| Service factor percentage | 115 % |
| Object classification code | Q |
| Signal indication fault | Red |
| Integrated electronic overload | Yes |
| Connecting capacity main circuit | Rigid 1 x 10 ... 95 mm² |
| Connecting capacity supply circuit | Rigid 1 x 2.5 |
| Signal indication protection | Yellow |
| Connecting capacity control circuit | Rigid 1 x 2.5 mm² |
| Popular downloads (Instructions and manuals) | 1SFC132003M0201 |
| Popular downloads (Data sheet, technical information) | 1SFC132005C0201 |
Product details
Frequently asked questions
Where can I buy 1SFA894003R7000 and get a price?
This part is sourced to order through independent distribution. Submit an RFQ — availability and current pricing are confirmed at quote time.
What is the ramp time range on the 1SFA894003R7000?
The ramp time is adjustable from 0 to 120 seconds, covering soft starts from near-instantaneous to a gradual 2-minute acceleration.
What communication interface does this PST37 use?
It uses a standard FieldBusPlug interface, meaning an optional fieldbus adapter module plugs directly into the starter for PROFIBUS, DeviceNet, Modbus RTU, or other protocols.
What compliance documentation is available for 1SFA894003R7000?
The part carries a WEEE category of Small Equipment (B2B) and a RoHS declaration is noted as 'No declaration needed'. The datasheet reference is 1SFC132005C0201 and the manual is 1SFC132003M0201.