ABB 1SFA894005R7020 — Soft Starters

ABB PST50 1SFA894005R7020 Soft Starter, 50A In-Line, 25kW

MPN1SFA894005R7020
Obsolete

ABB, PST50 series, soft starter, order code 1SFA894005R7020, 50 A rated operational current in-line, 25 kW at 400 V, 0–120 s ramp time, 100–250 V AC control supply, screw terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

1SFA894005R7020 key specifications
ParameterValue
Terminal typeScrew Terminals
Product main typePST50
VoltageMain Circuit 208 ... 600 V AC
Initial voltage during start30 ... 70 %
Step down voltage special ramp100 ... 30 %
Rated control supply voltage100 ... 250 V AC
Rated control circuit voltageDC Operation 24 V
Current limit function1.5 ... 7xIe
Starting capacity at maximum rated current ie3xIe for 15s
Rated operational current - In-Line connection50 A
Rated operational current - inside delta connection85 A
Rated operational power - In-Line connection(400 V) 25 kW

All specifications

1SFA894005R7020 additional specifications
ParameterValue
Rated operational power - inside delta connectionat 400 V 45 kW
Rated frequency50/60 Hz
IP ratingacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
ProtocolFiledBusPlug(Standard)
Switch for inside delta connectionYes
Material compliance (Conflict minerals reporting template)9AKK108467A5658
Ramp time0 ... 120 second [unit of time]
Analog outputs0...10 volts
Run signal relayYes
Tightening torqueControl Circuit 0.5 N·m
Fault signal relayYes
Overload protectionBuild-in electronic overload protection
By-pass signal relayYes
Overload signal relayYes
Ambient air temperatureOperation 0 ... +50 °C
Service factor percentage115 %
Object classification codeQ
Signal indication faultRed
Integrated electronic overloadYes
Connecting capacity main circuitRigid 1 x 10 ... 95 mm²
Connecting capacity supply circuitRigid 1 x 2.5
Signal indication protectionYellow
Connecting capacity control circuitRigid 1 x 2.5 mm²
Popular downloads (Instructions and manuals)1SFC132003M0201
Popular downloads (Data sheet, technical information)1SFC132005C0201

Product details

The ABB 1SFA894005R7020 is a PST50 soft starter rated for 50 A in-line connection (Ie), delivering 25 kW at 400 V. In an inside-delta configuration it handles 85 A and 45 kW — the delta wiring shifts the current path so the starter sees phase current while the motor draws line current, effectively doubling the power throughput for the same unit. Ramp time is adjustable from 0 to 120 seconds, with an initial voltage during start settable between 30 and 70 %. A step-down special ramp can drop voltage from 100 down to 30 %. Current limit function spans 1.5 to 7 times Ie. These give you control over the acceleration profile for pumps, conveyors, or compressors — soft starting avoids mechanical shock and limits inrush. Built-in electronic overload protection is integrated, with separate fault, overload, by-pass, and run signal relays — all screw-terminal connections. The control supply accepts 100–250 V AC; a separate 24 V DC control circuit is also available for logic-level interfacing.

Main circuit terminals accept rigid 1 x 10 to 95 mm² cable; control and supply circuits take 1 x 2.5 mm². Screw terminals with a control-circuit tightening torque of 0.5 N·m. The main terminals carry an IP10 degree of protection per IEC 60529 and IEC 60947-1 — finger-safe against accidental contact but not sealed against dust or moisture, so the unit belongs inside an enclosure rated for the environment. Ambient operating temperature range is 0 to +50 °C, with a 115 % service factor — meaning it can run at 115 % of rated current without tripping the overload, useful for high-inertia starts or occasional overload conditions.

Frequently asked questions

Where can I buy 1SFA894005R7020 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the ramp time on this PST50 soft starter?

The ramp time is adjustable from 0 to 120 seconds, with initial voltage during start settable between 30 and 70 % and a step-down ramp from 100 down to 30 %.

What communication interface does 1SFA894005R7020 use?

The communication interface is listed as FieldBusPlug (Standard) — it accepts a fieldbus plug for network integration, but the specific protocol (PROFIBUS, DeviceNet, etc.) depends on the plug module fitted.

What compliance documentation is available for this ABB soft starter?

The material compliance notes WEEE category 5 (Small Equipment) and B2B classification. RoHS information is marked as 'No declaration needed'. Refer to the data sheet (1SFC132005C0201) and instruction manual (1SFC132003M0201) for full compliance details.

MPN
1SFA894005R7020