1SFA894015R7000 - ABB
PSTB370-600-70 Softstarter - 370 A - Main Circuit 208... 600 V AC
Specifications
| Parameter | Value |
|---|---|
| Terminal type | Main Circuit: Bars |
| Product main type | PSTB370 |
| Voltage | Main Circuit 208 ... 600 V AC |
| Initial voltage during start | 30 ... 70 % |
| Step down voltage special ramp | 100 ... 30 % |
| Rated control supply voltage | 100 ... 250 V AC |
| Rated control circuit voltage | DC Operation 24 V |
| Current limit function | 1.5 ... 7xIe |
| Starting capacity at maximum rated current ie | 3xIe for 15s |
| Rated operational current - In-Line connection | 370 A |
| Rated operational current - inside delta connection | 640 A |
| Rated operational power - In-Line connection | (400 V) 200 kW |
All specifications
| Parameter | Value |
|---|---|
| Rated operational power - inside delta connection | at 400 V 355 kW |
| Rated frequency | 50/60 Hz |
| IP rating | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
| Protocol | FiledBusPlug(Standard) |
| Switch for inside delta connection | Yes |
| Material compliance (Conflict minerals reporting template) | 9AKK108467A5658 |
| Ramp time | 0 ... 120 second [unit of time] |
| Analog outputs | 0...10 volts |
| Run signal relay | Yes |
| Tightening torque | Control Circuit 0.5 N·m |
| Fault signal relay | Yes |
| Overload protection | Build-in electronic overload protection |
| By-pass signal relay | Yes |
| Overload signal relay | Yes |
| Ambient air temperature | Operation 0 ... +50 °C |
| Service factor percentage | 115 % |
| Object classification code | Q |
| Signal indication fault | Red |
| Integrated electronic overload | Yes |
| Connecting capacity main circuit | Hole Diameter 10.5 mm |
| Connecting capacity supply circuit | Rigid 1 x 2.5 |
| Signal indication protection | Yellow |
| Connecting capacity control circuit | Rigid 1 x 2.5 mm² |
| Popular downloads (Instructions and manuals) | 1SFC132003M0201 |
| Popular downloads (Data sheet, technical information) | 1SFC132005C0201 |
Frequently asked questions
What is the replacement for 1SFA894015R7000?
Because the part is obsolete and buyers need a drop-in alternative to keep equipment running.
Is ABB 1SFA894015R7000 still available for purchase?
Buyers need to quickly determine if they can source the part or must look for a substitute.
What are the input voltage and current ratings of PSTB370-600-70?
Design engineers must confirm compatibility with their system before specifying or replacing the softstarter.
Where to buy ABB 1SFA894015R7000 softstarter?
Sourcing buyers need to find authorized distributors that still have stock or can quote lead times.
Does PSTB370-600-70 have built-in bypass?
Maintenance techs need to know if the softstarter includes a bypass for energy efficiency and troubleshooting.
What is the equivalent cross reference for 1SFA894015R7000?
Brokers and engineers need a direct cross to evaluate alternatives or suggest replacements when the original is EOL.