ABB 1SFA894020R7000 — Soft Starters

ABB PSTB1050 1SFA894020R7000 Softstarter, 1050 A

MPN1SFA894020R7000
Obsolete

ABB PSTB1050 softstarter, order code 1SFA894020R7000, 1050 A rated operational current in-line connection, 560 kW at 400 V, 0-120 s ramp time, built-in electronic overload protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

1SFA894020R7000 key specifications
ParameterValue
Terminal typeMain Circuit: Bars
Product main typePSTB1050
VoltageMain Circuit 208 ... 600 V AC
Initial voltage during start30 ... 70 %
Step down voltage special ramp100 ... 30 %
Rated control supply voltage100 ... 250 V AC
Rated control circuit voltageDC Operation 24 V
Current limit function1.5 ... 7xIe
Starting capacity at maximum rated current ie3xIe for 15s
Rated operational current - In-Line connection1050 A
Rated operational current - inside delta connection1810 A
Rated operational power - In-Line connection(400 V) 560 kW

All specifications

1SFA894020R7000 additional specifications
ParameterValue
Rated operational power - inside delta connectionat 400 V 1000 kW
Rated frequency50/60 Hz
IP ratingacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
ProtocolFiledBusPlug(Standard)
Switch for inside delta connectionYes
Material compliance (Conflict minerals reporting template)9AKK108467A5658
Ramp time0 ... 120 second [unit of time]
Analog outputs0...10 volts
Run signal relayYes
Tightening torqueControl Circuit 0.5 N·m
Fault signal relayYes
Overload protectionBuild-in electronic overload protection
By-pass signal relayYes
Overload signal relayYes
Ambient air temperatureOperation 0 ... +50 °C
Service factor percentage100 %
Object classification codeQ
Signal indication faultRed
Integrated electronic overloadYes
Connecting capacity main circuitHole Diameter 12.5 mm
Connecting capacity supply circuitRigid 1 x 2.5
Signal indication protectionYellow
Connecting capacity control circuitRigid 1 x 2.5 mm²
Popular downloads (Instructions and manuals)1SFC132003M0201
Popular downloads (Data sheet, technical information)1SFC132005C0201

Product details

The 1SFA894020R7000: The 0-120 second ramp time lets you tune acceleration for conveyors, pumps, or fans so the load doesn't jerk the driveline. Starting capacity is 3x Ie for 15 seconds, which covers most standard induction motor starts without oversizing.

The 1050 A in-line rating is the number you spec against the motor nameplate FLA — it's the continuous current the softstarter carries without bypass. The 1810 A inside-delta rating applies when you wire the softstarter in the motor's delta legs, which reduces the current through each device phase by a factor of √3; that's the configuration that gets you 1000 kW from a single unit. Built-in electronic overload protection (1.5-7x Ie current limit function) means you can omit a separate overload relay from the starter assembly — one less component to wire and panel-space to budget. The run, fault, bypass, and overload signal relays give the PLC a clean status picture without adding interface modules. Main circuit terminals are bars with a 12.5 mm hole — expect to land lugs, not ferrules. Control circuit torque is 0.5 N·m; the supply circuit accepts rigid 1 x 2.5 mm². The FiledBusPlug (Standard) communication interface lets you drop a fieldbus connector directly onto the unit without a separate gateway card.

RoHS compliance is declared as 'no declaration needed' — the part falls under WEEE Category 4 (Large Equipment, any external dimension >50 cm), B2B scope. The relevant manual is 1SFC132003M0201 and the datasheet is 1SFC132005C0201.

Frequently asked questions

How do I get current pricing and availability for 1SFA894020R7000?

Pricing and availability are confirmed at quote time. Submit an RFQ through this listing; we source the part from our multi-distributor network and return a current price and lead-time commitment.

What is 1SFA894020R7000's listed ramp time?

The ramp time is adjustable from 0 to 120 seconds. This lets you match the acceleration profile to the load — short for low-inertia fans, longer for conveyors or high-inertia pumps.

What is the closest alternative to this PSTB1050 softstarter?

Within the same PSTB family, the PSTB1050 is the 1050 A in-line variant. The next step down is the PSTB850 (850 A in-line) and the step up is the PSTB1250 (1250 A in-line). All share the same form factor, control voltage options, and fieldbus plug interface — the swap is purely a current-rating decision.

MPN
1SFA894020R7000