Skip to main content
ABB 1SFA895002R7000 — Soft Starters

ABB PST30 Softstarter 1SFA895002R7000, 30 A In-Line, 52 A De

MPN1SFA895002R7000
Obsolete

ABB PST30 softstarter, order code 1SFA895002R7000, 30 A in-line / 52 A inside-delta, 400–690 V AC main circuit, 0–120 s ramp, built-in electronic overload, screw terminals, FiledBusPlug communication.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

1SFA895002R7000 key specifications
ParameterValue
Terminal typeScrew Terminals
Product main typePST30
VoltageMain Circuit 400 ... 690 V AC
Initial voltage during start30 ... 70 %
Step down voltage special ramp100 ... 30 %
Rated control supply voltage100 ... 250 V AC
Rated control circuit voltageDC Operation 24 V
Current limit function1.5 ... 7xIe
Starting capacity at maximum rated current ie3xIe for 15s
Rated operational current - In-Line connection30 A
Rated operational current - inside delta connection52 A
Rated operational power - In-Line connection(400 V) 15 kW

All specifications

1SFA895002R7000 additional specifications
ParameterValue
Rated operational power - inside delta connectionat 400 V 25 kW
Rated frequency50/60 Hz
IP ratingacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
ProtocolFiledBusPlug(Standard)
Switch for inside delta connectionYes
Material compliance (Conflict minerals reporting template)9AKK108467A5658
Ramp time0 ... 120 second [unit of time]
Analog outputs0...10 volts
Run signal relayYes
Tightening torqueControl Circuit 0.5 N·m
Fault signal relayYes
Overload protectionBuild-in electronic overload protection
By-pass signal relayYes
Overload signal relayYes
Ambient air temperatureOperation 0 ... +50 °C
Service factor percentage115 %
Object classification codeQ
Signal indication faultRed
Integrated electronic overloadYes
Connecting capacity main circuitRigid 1 x 10 ... 95 mm²
Connecting capacity supply circuitRigid 1 x 2.5
Signal indication protectionYellow
Connecting capacity control circuitRigid 1 x 2.5 mm²
Popular downloads (Instructions and manuals)1SFC132003M0201
Popular downloads (Data sheet, technical information)1SFC132005C0201

Product details

The 1SFA895002R7000: Ramp time is adjustable from 0 to 120 seconds, with initial voltage during start settable between 30 and 70 percent, and a step-down special ramp from 100 to 30 percent. This range covers soft starts for conveyors, pumps, and fans where gradual acceleration and deceleration reduce mechanical shock. The main circuit accepts 400 to 690 V AC at 50/60 Hz, with a 115 percent service factor for continuous overload margin. Control supply voltage is 100–250 V AC; a separate 24 V DC control circuit is available for logic-level interfacing.

Integration and Connectivity

Communication is via a standard FiledBusPlug interface, allowing direct connection to fieldbus networks without additional adapters. Screw terminals on the control circuit accept 1 x 2.5 mm² rigid wire; main circuit terminals accept 1 x 10 to 95 mm² rigid. Tightening torque for control circuit terminals is 0.5 N·m. A red LED indicates a fault condition; a yellow LED signals protection activation. An analog output of 0–10 V is provided for external metering or drive profiling. The inside-delta connection switch is built in, enabling the higher 52 A / 25 kW rating without external contactors.

Frequently asked questions

What is the ramp time range on this softstarter?

The ramp time is adjustable from 0 to 120 seconds, with initial voltage during start from 30 to 70 percent and a step-down ramp from 100 to 30 percent.

What communication interface does 1SFA895002R7000 use?

It uses a standard FiledBusPlug interface for direct fieldbus connection.

What compliance documentation is available for this part?

The part is classified as B2B under WEEE (Category 5, small equipment). RoHS declaration is noted as 'no declaration needed' — verify with the manufacturer for specific market requirements.

MPN
1SFA895002R7000