Screw terminals on the control circuit (0.5 N·m tightening torque) accept 1 × 2.5 mm² rigid. Main circuit terminals accept 1 × 10…95 mm² rigid — sized for the 60 A feed. Supply circuit connection is 1 × 2.5 mm². Degree of protection on the main terminals is IP10 per IEC 60529 / IEC 60947-1 — basic finger-probe protection. The unit is intended for enclosure mounting; ambient operating temperature range is 0…+50 °C. Communication interface is FieldBusPlug (Standard), the ABB plug-in fieldbus adapter format. The unit also provides run, fault, bypass, and overload signal relays — four discrete outputs for the PLC or HMI without extra I/O modules.
ABB PST60 1SFA895006R7000 Softstarter, 60 A In-Line, 30 kW
MPN1SFA895006R7000
Obsolete
ABB PST60 series softstarter, order code 1SFA895006R7000, 60 A in-line rated operational current, 30 kW at 400 V, 24 V DC control, screw terminals, FieldBusPlug communication.
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
Specifications
| Parameter | Value |
|---|---|
| Terminal type | Screw Terminals |
| Product main type | PST60 |
| Voltage | Main Circuit 400 ... 690 V AC |
| Initial voltage during start | 30 ... 70 % |
| Step down voltage special ramp | 100 ... 30 % |
| Rated control circuit voltage | DC Operation 24 V |
| Current limit function | 1.5 ... 7xIe |
| Starting capacity at maximum rated current ie | 3xIe for 15s |
| Rated operational current - In-Line connection | 60 A |
| Rated operational current - inside delta connection | 105 A |
| Rated operational power - In-Line connection | (400 V) 30 kW |
| Rated operational power - inside delta connection | at 400 V 55 kW |
All specifications
| Parameter | Value |
|---|---|
| Rated frequency | 50/60 Hz |
| IP rating | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
| Protocol | FiledBusPlug(Standard) |
| Switch for inside delta connection | Yes |
| Material compliance (Conflict minerals reporting template) | 9AKK108467A5658 |
| Ramp time | 0 ... 120 second [unit of time] |
| Analog outputs | 0...10 volts |
| Run signal relay | Yes |
| Tightening torque | Control Circuit 0.5 N·m |
| Fault signal relay | Yes |
| Overload protection | Build-in electronic overload protection |
| By-pass signal relay | Yes |
| Overload signal relay | Yes |
| Ambient air temperature | Operation 0 ... +50 °C |
| Service factor percentage | 115 % |
| Object classification code | Q |
| Signal indication fault | Red |
| Integrated electronic overload | Yes |
| Connecting capacity main circuit | Rigid 1 x 10 ... 95 mm² |
| Connecting capacity supply circuit | Rigid 1 x 2.5 |
| Signal indication protection | Yellow |
| Connecting capacity control circuit | Rigid 1 x 2.5 mm² |
| Popular downloads (Instructions and manuals) | 1SFC132003M0201 |
| Popular downloads (Data sheet, technical information) | 1SFC132005C0201 |
Product details
Frequently asked questions
What is the ramp time range on this PST60 softstarter?
Adjustable 0 to 120 seconds, with initial voltage during start settable 30 to 70 %.
What communication interface does 1SFA895006R7000 use?
FieldBusPlug (Standard) — the ABB plug-in fieldbus adapter format for PROFIBUS, DeviceNet, or similar modules.
Does this softstarter include overload protection?
Yes, built-in electronic overload protection with current limit function adjustable 1.5 to 7× Ie.
MPN
1SFA895006R7000