The ABB PST210 softstarter 1SFA895012R7020 is rated 210 A in-line connection (Ie), delivering 110 kW at 400 V, with an inside-delta rating of 360 A and 184 kW at 400 V. Main circuit voltage range is 400-690 V AC, 50/60 Hz. Control supply is 100-250 V AC; a separate 24 V DC control circuit is also available. Built-in electronic overload protection is standard, with a current limit function adjustable 1.5-7x Ie. Ramp time is adjustable 0-120 s, with initial voltage 30-70 % and step-down voltage 100-30 %.

ABB PST210 1SFA895012R7020 Softstarter, 210 A, 110 kW
MPN1SFA895012R7020
Obsolete
ABB PST210 softstarter, order code 1SFA895012R7020, 210 A in-line rated current, 110 kW at 400 V, 400-690 V AC, built-in electronic overload, ramp 0-120 s.
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Terminal type | Main Circuit: Bars |
| Product main type | PST210 |
| Voltage | Main Circuit 400 ... 690 V AC |
| Initial voltage during start | 30 ... 70 % |
| Step down voltage special ramp | 100 ... 30 % |
| Rated control supply voltage | 100 ... 250 V AC |
| Rated control circuit voltage | DC Operation 24 V |
| Current limit function | 1.5 ... 7xIe |
| Starting capacity at maximum rated current ie | 3xIe for 15s |
| Rated operational current - In-Line connection | 210 A |
| Rated operational current - inside delta connection | 360 A |
| Rated operational power - In-Line connection | (400 V) 110 kW |
All specifications
| Parameter | Value |
|---|---|
| Rated operational power - inside delta connection | at 400 V 184 kW |
| Rated frequency | 50/60 Hz |
| IP rating | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
| Protocol | FiledBusPlug(Standard) |
| Switch for inside delta connection | Yes |
| Material compliance (Conflict minerals reporting template) | 9AKK108467A5658 |
| Ramp time | 0 ... 120 second [unit of time] |
| Analog outputs | 0...10 volts |
| Run signal relay | Yes |
| Tightening torque | Control Circuit 0.5 N·m |
| Fault signal relay | Yes |
| Overload protection | Build-in electronic overload protection |
| By-pass signal relay | Yes |
| Overload signal relay | Yes |
| Ambient air temperature | Operation 0 ... +50 °C |
| Service factor percentage | 115 % |
| Object classification code | Q |
| Signal indication fault | Red |
| Integrated electronic overload | Yes |
| Connecting capacity main circuit | Hole Diameter 10.2 mm |
| Connecting capacity supply circuit | Rigid 1 x 2.5 |
| Signal indication protection | Yellow |
| Connecting capacity control circuit | Rigid 1 x 2.5 mm² |
| Popular downloads (Instructions and manuals) | 1SFC132003M0201 |
| Popular downloads (Data sheet, technical information) | 1SFC132005C0201 |
Product details
Frequently asked questions
What is the ramp time for 1SFA895012R7020?
The ramp time is adjustable from 0 to 120 seconds.
What communication interface does 1SFA895012R7020 use?
It uses a standard FieldBusPlug for communication.
Where can I buy 1SFA895012R7020?
This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.
MPN
1SFA895012R7020