Skip to main content
ABB 1SFA895019R7000 — Soft Starters

ABB PSTB840 1SFA895019R7000 Softstarter, 840 A In-Line, 450

MPN1SFA895019R7000
Obsolete

ABB PSTB840 softstarter, order code 1SFA895019R7000, 840 A in-line rated operational current, 450 kW at 400 V, 400-690 V AC main circuit, built-in electronic overload protection, ramp time 0-120 s, FieldBusPlug communication.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

1SFA895019R7000 key specifications
ParameterValue
Terminal typeMain Circuit: Bars
Product main typePSTB840
VoltageMain Circuit 400 ... 690 V AC
Initial voltage during start30 ... 70 %
Step down voltage special ramp100 ... 30 %
Rated control supply voltage100 ... 250 V AC
Rated control circuit voltageDC Operation 24 V
Current limit function1.5 ... 7xIe
Starting capacity at maximum rated current ie3xIe for 15s
Rated operational current - In-Line connection840 A
Rated operational current - inside delta connection1455 A
Rated operational power - In-Line connection(400 V) 450 kW

All specifications

1SFA895019R7000 additional specifications
ParameterValue
Rated operational power - inside delta connectionat 400 V 800 kW
Rated frequency50/60 Hz
IP ratingacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
ProtocolFiledBusPlug(Standard)
Switch for inside delta connectionYes
Material compliance (Conflict minerals reporting template)9AKK108467A5658
Ramp time0 ... 120 second [unit of time]
Analog outputs0...10 volts
Run signal relayYes
Tightening torqueControl Circuit 0.5 N·m
Fault signal relayYes
Overload protectionBuild-in electronic overload protection
By-pass signal relayYes
Overload signal relayYes
Ambient air temperatureOperation 0 ... +50 °C
Service factor percentage115 %
Object classification codeQ
Signal indication faultRed
Integrated electronic overloadYes
Connecting capacity main circuitHole Diameter 12.5 mm
Connecting capacity supply circuitRigid 1 x 2.5
Signal indication protectionYellow
Connecting capacity control circuitRigid 1 x 2.5 mm²
Popular downloads (Instructions and manuals)1SFC132003M0201
Popular downloads (Data sheet, technical information)1SFC132005C0201

Product details

The 1SFA895019R7000: The 840 A in-line rating (Ie) is the continuous current the softstarter can handle in a standard motor circuit — this decides the cable and contactor sizing upstream. The 450 kW at 400 V figure tells you the maximum motor power it can start in-line; for inside-delta wiring, that jumps to 800 kW at 400 V, which is the configuration used to reduce the current through the main thyristors for larger motors. The 400-690 V AC main circuit voltage range covers low-voltage networks from 400 V three-phase up to 690 V industrial supplies — common in mining, cement, and marine installations. The built-in electronic overload protection eliminates the need for a separate overload relay, saving panel space and wiring.

Integration notes

The main circuit terminals are bars (hole diameter 12.5 mm), sized for large cable lugs or busbar connections typical of high-current panels. The control circuit connects via rigid 1 x 2.5 mm² wire with a tightening torque of 0.5 N·m. The FieldBusPlug standard communication interface allows direct connection to a fieldbus network via an optional plug-in module — no separate gateway needed. Ambient operating temperature range is 0 to +50 °C, with a 115 % service factor for continuous overload capability.

Frequently asked questions

Where can I buy 1SFA895019R7000 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the ramp time range for this softstarter?

The ramp time is adjustable from 0 to 120 seconds, allowing soft starting of motors with gradual acceleration to match load requirements.

What communication interface does 1SFA895019R7000 use?

It uses a FieldBusPlug standard interface, which accepts an optional plug-in communication module for fieldbus connectivity (e.g., PROFIBUS, DeviceNet, or similar).

What compliance documentation is available for this part?

The part carries a WEEE category of Large Equipment (B2B) and RoHS information is marked as 'No declaration needed'. The manufacturer provides a data sheet (1SFC132005C0201) and instruction manual (1SFC132003M0201) for detailed compliance and installation guidance.

MPN
1SFA895019R7000