ABB 1SFA896104R1100 PSR6 Softstarter, 208-600 V AC

MPN1SFA896104R1100
Active

ABB PSR6 series soft starter, order code 1SFA896104R1100, rated 208... 600 V AC at 50/60 Hz with 24 V AC/DC control supply and 0... 20 s adjustable voltage ramp.

$208.00Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

1SFA896104R1100 key specifications
ParameterValue
Terminal typeScrew Terminals
Product main typePSR6
Voltage208 ... 600 V AC
Initial voltage during start40 ... 70 %
Step down voltage special ramp100 ... 60 %
Rated control supply voltage24 V AC/DC
Rated control circuit voltage24 V DC
Technical UL (CSA, maximum operating voltage UL, CSA)Main Circuit 600 V
Current limit functionNo
Starting capacity at maximum rated current ie4xIe for 6s
Rated operational current - In-Line connection6.8 A
Technical UL (CSA, horsepower rating UL, CSA)(200 ... 208 V AC) Three Phase 1 Hp
All specifications+33
1SFA896104R1100 additional specifications
ParameterValue
Rated operational power - In-Line connection(230 V) 1.5 kW
Rated frequency50/60 Hz
IP ratingacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
ProtocolFiledBusPlug(Optional)
Switch for inside delta connectionNo
Popular downloads (CAD dimensional drawing)2CDC001079B0201
Material compliance (Toxic substances control act - TSCA)2CMT2023-006524
Material compliance (Conflict minerals reporting template)9AKK108467A5658
Technical UL (CSA, tightening torque UL, CSA)Control Circuit 8.9 in·lb
FunctionSoft start with voltage ramp
Ramp time0 ... 20 second [unit of time]
Run signal relayYes
Tightening torqueControl Circuit 1 N·m
Fault signal relayNo
Overload protectionRecommended MS116 4.00 ... 10.00
By-pass signal relayNo
Overload signal relayNo
Ambient air temperatureOperation -25 ... +60 °C
Service factor percentage100 %
Object classification codeQ
Popular downloads (EPLAN data)9AAC129233_EPLAN
Integrated electronic overloadNo
Connecting capacity main circuitRigid 1/2 x 0.75 ... 2.5 mm²
Popular downloads (Wiring diagram)1SFC132030M0001
Signal indication running rGreen
Connecting capacity supply circuitRigid 1/2 x 0.75 ... 2.5
IDEA granular category code4740 >> Soft starter
Connecting capacity control circuit1 x 0.75 ... 2.5 mm²
Signal indication ramping up (Down)Green
Popular downloads (Instructions and manuals)1SFC132076M9901
Signal indication completed start rampGreen
Popular downloads (Data sheet, technical information)1SFC132012C0201
Popular Downloads/Instructions and manuals (Part 3)1SFC132060M0201

Product details

What it does on the panel

The ABB 1SFA896104R1100 is a PSR6-class soft starter that brings a three-phase motor up on a voltage ramp rather than a step-start, so the inrush and mechanical shock on a coupled load stay bounded. The starting envelope is set by an initial voltage of 40... 70 % of line and a ramp time of 0... 20 second, with a complementary step-down profile of 100... 60 % for the special-ramp stop mode. That pair of knobs is what the panel builder dials in for the specific pump, fan, or conveyor the device is feeding. Main-circuit voltage is rated 208... 600 V AC at 50/60 Hz, and the unit takes its control power from a 24 V AC/DC supply, with a separately listed 24 V DC control-circuit rating. The control-circuit terminal is torqued to 1 N·m, and the main circuit accepts rigid conductors from 0.75... 2.5 mm². It runs across an ambient range of -25... +60 °C, so it sits comfortably in an unventilated cabinet provided the cabinet derating is observed.

Protection coordination

There is no integrated electronic overload on this model — thermal protection is handled by an external device, with ABB calling out the MS116 4.00... 10.00 A range as the recommended match. The control supply is 24 V AC/DC, which keeps the holding coil and the logic on a common transformer tap. The fault, overload, and bypass signal relays are all marked absent; the only signalling contact the panel needs to land is the run signal relay.

The device is classified B2B under WEEE category 5 (small equipment, no external dimension over 50 cm) and is documented as compliant with EU Directive 2011/65/EU and Amendment 2015/863 of 22 July 2019. Main terminals carry IP20 per IEC 60529 / IEC 60947-1 / EN 60529, which is the standard finger-safe rating for a back-of-panel mount. CAD dimensional data, the EPLAN dataset, and the wiring diagram are all published as separate documents on the ABB download channel.

Frequently asked questions

What is the listed function of the 1SFA896104R1100 on this soft-starter line?

The listed function is soft start with voltage ramp, on the PSR6 product main type, with an initial voltage of 40... 70 % of line and a ramp time of 0... 20 second.

What is the listed ramp time of the 1SFA896104R1100?

Ramp time is 0... 20 second, adjustable. The initial voltage during start is 40... 70 % of line, and the special-ramp step-down profile is 100... 60 %.

What overload protection does the 1SFA896104R1100 pair with?

There is no integrated electronic overload on the 1SFA896104R1100. The ABB recommendation is an external MS116 4.00... 10.00 A motor protector.

What compliance documentation does ABB provide for the 1SFA896104R1100?

The part is documented as compliant with EU Directive 2011/65/EU and Amendment 2015/863 of 22 July 2019, classified WEEE B2B category 5, with main terminals at IP20 per IEC 60529, IEC 60947-1, and EN 60529. EPLAN data, CAD dimensions, and the wiring diagram are published as separate downloads.