ABB 1SFA896105R1100

ABB 1SFA896105R1100 PSR9 Softstarter, 208-600 V AC

MPN1SFA896105R1100
Active

ABB, PSR9 series softstarter, order code 1SFA896105R1100, rated 208–600 V AC with 0–20 s voltage ramp and 24 V AC/DC control supply.

$243.00Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

1SFA896105R1100 key specifications
ParameterValue
Terminal typeScrew Terminals
Product main typePSR9
Voltage208 ... 600 V AC
Initial voltage during start40 ... 70 %
Step down voltage special ramp100 ... 60 %
Rated control supply voltage24 V AC/DC
Rated control circuit voltage24 V DC
Technical UL (CSA, maximum operating voltage UL, CSA)Main Circuit 600 V
Current limit functionNo
Starting capacity at maximum rated current ie4xIe for 6s
Rated operational current - In-Line connection9 A
Technical UL (CSA, horsepower rating UL, CSA)(200 ... 208 V AC) Three Phase 2 Hp
All specifications+32
1SFA896105R1100 additional specifications
ParameterValue
Rated operational power - In-Line connection(230 V) 2.2 kW
Rated frequency50/60 Hz
IP ratingacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
ProtocolFiledBusPlug(Optional)
Switch for inside delta connectionNo
Popular downloads (CAD dimensional drawing)2CDC001079B0201
Material compliance (Toxic substances control act - TSCA)2CMT2023-006524
Material compliance (Conflict minerals reporting template)9AKK108467A5658
Technical UL (CSA, tightening torque UL, CSA)Control Circuit 8.9 in·lb
FunctionSoft start with voltage ramp
Ramp time0 ... 20 second [unit of time]
Run signal relayYes
Tightening torqueControl Circuit 1 N·m
Fault signal relayNo
Overload protectionRecommended MS116 6.30 ... 10.00
By-pass signal relayNo
Overload signal relayNo
Ambient air temperatureOperation -25 ... +60 °C
Service factor percentage100 %
Object classification codeQ
Popular downloads (EPLAN data)9AAC129234_EPLAN
Integrated electronic overloadNo
Connecting capacity main circuitRigid 1/2 x 0.75 ... 2.5 mm²
Signal indication running rGreen
Connecting capacity supply circuitRigid 1/2 x 0.75 ... 2.5
IDEA granular category code4740 >> Soft starter
Connecting capacity control circuit1 x 0.75 ... 2.5 mm²
Signal indication ramping up (Down)Green
Popular downloads (Instructions and manuals)1SFC132076M9901
Signal indication completed start rampGreen
Popular downloads (Data sheet, technical information)1SFC132012C0201
Popular Downloads/Instructions and manuals (Part 3)1SFC132060M0201

Product details

PSR9 in the panel

The ABB 1SFA896105R1100 is a PSR9-class soft starter that ramps the motor up with a voltage ramp over 0…20 s, sized for 208…600 V AC at 50/60 Hz on three-phase mains. It is built for a 4xIe for 6s starting duty — the figure that decides whether a given motor fits — so the motor's locked-rotor current and load inertia need to come in under that envelope. Initial voltage during start is adjustable from 40…70 % of line, with a step-down special ramp of 100…60 % available for the deceleration side. That trims the mechanical shock on the coupling without adding a separate braking device.

Control-side wiring and what it does not do

The control supply is 24 V AC/DC on the Uc terminal, wired through screw terminals torqued to 1 N·m on the control circuit. Main terminals are IP20 per IEC 60529 / IEC 60947-1, so finger-safe but not dust- or water-protected — cabinet mounting is mandatory. There is no integrated electronic overload on this PSR9; ABB pairs it with an MS116 6.30…10.00 thermal overload block for the motor protection line. Run signal relay is present (green LED), fault, overload and by-pass signal relays are not — a status-only device, not a fault annunciator.

Ambient and connection envelope

Operation is rated -25…+60 °C ambient. Main-circuit and supply-circuit connecting capacity is rigid 1/2 x 0.75…2.5 mm²; control circuit takes 1 x 0.75…2.5 mm². The UL/CSA frame rating is 2 Hp at 200…208 V AC three-phase, with control-circuit tightening torque 8.9 in·lb on the UL side.

Compliance paperwork

RoHS compliance follows EU Directive 2011/65/EU and Amendment 2015/863 of 22 July 2019; the part is WEEE Category 5 small equipment and is sold Business-To-Business, not through consumer channels. A FiledBusPlug fieldbus connection is optional, not fitted by default — a Modbus or anybus add-on would be a separate order line against this PSR9 base.

Frequently asked questions

What is the closest functional second-source to 1SFA896105R1100?

The closest functional alternative in the same PSR line is the 1SFA896106R1100, with 1SFA896104R1100 and 1SFA896104R7000 as adjacent PSR9 frames. Treat them as the same family only after verifying the matching motor current and voltage class — not as drop-in equivalents.

What is 1SFA896105R1100's listed function on this Softstarter line?

Soft start with voltage ramp, per the spec entry — the device ramps motor voltage from an adjustable 40…70 % initial level to full line over 0…20 s.

What is 1SFA896105R1100's listed ramp time?

0…20 seconds, user-adjustable. Pick a ramp that holds starting current under the 4xIe for 6s envelope for the driven load.

Will 1SFA896105R1100 drop into a panel specified around 1SFA896106R1100 without rewiring?

Both are PSR9 soft starters in the same wiring topology — same 24 V AC/DC control supply and same screw-terminal main circuit layout — but the current class differs between the two PSR codes. Verify the motor FLA and the matching MS116 overload range before swapping; do not treat them as a like-for-like cross.

What compliance documentation does ABB provide for 1SFA896105R1100?

RoHS compliance per EU Directive 2011/65/EU and Amendment 2015/863 of 22 July 2019; WEEE Category 5 (small equipment); sold Business-To-Business. UL/CSA rating to 2 Hp at 200…208 V AC three-phase is stated.