1SFA898111R7000 - ABB
MPN1SFA898111R7000
Active
Soft starter
$2,226.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
Specifications
| Parameter | Value |
|---|---|
| Terminal type | Main Circuit: Bars |
| Product main type | PSTX170 |
| Voltage | 208 ... 600 V AC |
| Initial voltage during start | 10 ... 99 % |
| Step down voltage special ramp | 100 ... 10 % |
| Rated control supply voltage | 100 ... 250 V AC |
| Rated control circuit voltage | 24 V DC |
| Technical UL (CSA, maximum operating voltage UL, CSA) | Main Circuit 600 V |
| Current limit function | 1.5 ... 7.5 xle |
| Starting capacity at maximum rated current ie | 4xIe for 10s |
| Rated operational current - In-Line connection | 170 A |
| Rated operational current - inside delta connection | 300 A |
All specifications
| Parameter | Value |
|---|---|
| Technical UL (CSA, horsepower rating UL, CSA) | (200 ... 208 V AC) Three Phase 50 Hp |
| Rated operational power - In-Line connection | (230 V) 45 kW |
| Rated operational power - inside delta connection | at 230 V 90 kW |
| Rated frequency | 50/60 Hz |
| IP rating | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
| Protocol | Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP |
| Switch for inside delta connection | Yes |
| Popular downloads (CAD dimensional drawing) | 2CDC001079B0201 |
| Material compliance (Toxic substances control act - TSCA) | 2CMT2023-006524 |
| Material compliance (Conflict minerals reporting template) | 9AKK108467A5658 |
| Technical UL (CSA, tightening torque UL, CSA) | Main Circuit 123.9 |
| Function | Auto phase sequence detection |
| Ramp time | 1 ... 120 second [unit of time] |
| Analog outputs | 0...10 V, 0...20 mA, 4...20 mA |
| Warning details | Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning |
| Run signal relay | Yes |
| Tightening torque | Main Circuit 14 N·m |
| Fault signal relay | Yes |
| Overload protection | Built-in electronic overload protection |
| Protection function | Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection |
| By-pass signal relay | Yes |
| Overload signal relay | Yes |
| Ambient air temperature | Operation -25 ... +60 °C |
| Service factor percentage | 100 % |
| Object classification code | Q |
| Popular downloads (EPLAN data) | 9AAC181167_EPLAN |
| Signal indication fault | Red |
| Integrated electronic overload | Yes |
| Connecting capacity main circuit | Hole Diameter 8.5 mm |
| Signal indication running r | Green |
| Connecting capacity supply circuit | Rigid 1 x 2.5 |
| IDEA granular category code | 4740 >> Soft starter |
| Signal indication protection | Yellow |
| Connecting capacity control circuit | Rigid 1 x 2.5 mm² |
| Popular downloads (Instructions and manuals) | 1SFC132428M0201 |
| Popular downloads (Data sheet, technical information) | 1SFC132012C0201 |
| Popular Downloads/Instructions and manuals (Part 2) | 1SFC132081M0201 |
| Popular Downloads/Instructions and manuals (Part 3) | 1SFC132060M0201 |