Skip to main content
ABB 1SFA898113R7000 — Soft Starters

ABB 1SFA898113R7000 PSTX250 Soft Starter, 208-600 V AC

MPN1SFA898113R7000
Active

ABB PSTX250 soft starter, order code 1SFA898113R7000, auto phase sequence detection, 208-600 V AC, 50/60 Hz, multi-protocol communication.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

1SFA898113R7000 key specifications
ParameterValue
Terminal typeMain Circuit: Bars
Product main typePSTX250
Voltage208 ... 600 V AC
Initial voltage during start10 ... 99 %
Step down voltage special ramp100 ... 10 %
Rated control supply voltage100 ... 250 V AC
Rated control circuit voltage24 V DC
Technical UL (CSA, maximum operating voltage UL, CSA)Main Circuit 600 V
Current limit function1.5 ... 7.5 xle
Starting capacity at maximum rated current ie4xIe for 10s
Rated operational current - In-Line connection250 A
Rated operational current - inside delta connection430 A

All specifications

1SFA898113R7000 additional specifications
ParameterValue
Technical UL (CSA, horsepower rating UL, CSA)(200 ... 208 V AC) Three Phase 75 Hp
Rated operational power - In-Line connection(230 V) 75 kW
Rated operational power - inside delta connectionat 230 V 132 kW
Rated frequency50/60 Hz
IP ratingacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
ProtocolModbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Switch for inside delta connectionYes
Popular downloads (CAD dimensional drawing)2CDC001079B0201
Material compliance (Toxic substances control act - TSCA)2CMT2023-006524
Material compliance (Conflict minerals reporting template)9AKK108467A5658
Technical UL (CSA, tightening torque UL, CSA)Main Circuit 221.3
FunctionAuto phase sequence detection
Ramp time1 ... 120 second [unit of time]
Analog outputs0...10 V, 0...20 mA, 4...20 mA
Warning detailsCurrent imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Run signal relayYes
Tightening torqueMain Circuit 25 N·m
Fault signal relayYes
Overload protectionBuilt-in electronic overload protection
Protection functionBypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
By-pass signal relayYes
Overload signal relayYes
Ambient air temperatureOperation -25 ... +60 °C
Service factor percentage100 %
Object classification codeQ
Popular downloads (EPLAN data)9AAC181169_EPLAN
Signal indication faultRed
Integrated electronic overloadYes
Connecting capacity main circuitHole Diameter 10.2 mm
Signal indication running rGreen
Connecting capacity supply circuitRigid 1 x 2.5
IDEA granular category code4740 >> Soft starter
Signal indication protectionYellow
Connecting capacity control circuitRigid 1 x 2.5 mm²
Popular downloads (Instructions and manuals)1SFC132428M0201
Popular downloads (Data sheet, technical information)1SFC132012C0201
Popular Downloads/Instructions and manuals (Part 2)1SFC132081M0201
Popular Downloads/Instructions and manuals (Part 3)1SFC132060M0201

Product details

The ABB 1SFA898113R7000 is a PSTX250 soft starter with auto phase sequence detection, rated for 208-600 V AC at 50/60 Hz. It accepts a control supply of 100-250 V AC and a separate 24 V DC control circuit, so the logic side stays isolated from the power loop — useful when a PLC cabinet runs on 24 V and the motor circuit is 400 V.

Protection and communication

Built-in electronic overload protection covers locked rotor, current imbalance, earth fault, phase reversal, and under/over voltage — 22 protection functions in total, configurable per motor duty. The unit communicates over Modbus RTU, Modbus TCP, EtherNet/IP, EtherCAT, DeviceNet, CANopen, PROFIBUS, PROFINET, BACnet IP, and BACnet MSTP, so it fits into nearly any control architecture without a gateway.

RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863. WEEE category 5 (small equipment). CAD dimensional drawing and EPLAN data are available for panel integration.

Frequently asked questions

What is the function of 1SFA898113R7000?

Its primary function is auto phase sequence detection on a soft starter, ensuring the motor rotates in the correct direction on startup.

What is the ramp time range for this soft starter?

The ramp time is adjustable from 1 to 120 seconds, allowing a controlled acceleration profile for the connected motor load.

What communication protocols does 1SFA898113R7000 support?

It supports Modbus RTU, Modbus TCP, EtherNet/IP, EtherCAT, DeviceNet, CANopen, PROFIBUS, PROFINET, BACnet IP, and BACnet MSTP.

What compliance documentation is available for 1SFA898113R7000?

The part is RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863. CAD dimensional drawings and EPLAN data are available for integration planning.

Where can I buy 1SFA898113R7000?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN