Skip to main content
ABB 1SFA898120R7000 — Soft Starters

ABB 1SFA898120R7000 PSTX1050 Soft Starter, 400 HP, 208-600 V

MPN1SFA898120R7000
Active

ABB PSTX1050 soft starter, 1SFA898120R7000, 208-600 V AC, 400 HP at 200-208 V, built-in electronic overload, multi-protocol communication.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

1SFA898120R7000 key specifications
ParameterValue
Terminal typeMain Circuit: Bars
Product main typePSTX1050
Voltage208 ... 600 V AC
Initial voltage during start10 ... 99 %
Step down voltage special ramp100 ... 10 %
Rated control supply voltage100 ... 250 V AC
Rated control circuit voltage24 V DC
Technical UL (CSA, maximum operating voltage UL, CSA)Main Circuit 600 V
Current limit function1.5 ... 7.5 xle
Starting capacity at maximum rated current ie4xIe for 10s
Rated operational current - In-Line connection1050 A
Rated operational current - inside delta connection1810 A

All specifications

1SFA898120R7000 additional specifications
ParameterValue
Technical UL (CSA, horsepower rating UL, CSA)(200 ... 208 V AC) Three Phase 400 Hp
Rated operational power - In-Line connection(230 V) 315 kW
Rated operational power - inside delta connectionat 230 V 500 kW
Rated frequency50/60 Hz
IP ratingacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
ProtocolModbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Switch for inside delta connectionYes
Popular downloads (CAD dimensional drawing)2CDC001079B0201
Material compliance (Toxic substances control act - TSCA)2CMT2023-006524
Material compliance (Conflict minerals reporting template)9AKK108467A5658
Technical UL (CSA, tightening torque UL, CSA)Main Circuit 398.3
FunctionAuto phase sequence detection
Ramp time1 ... 120 second [unit of time]
Analog outputs0...10 V, 0...20 mA, 4...20 mA
Warning detailsCurrent imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Run signal relayYes
Tightening torqueMain Circuit 45 N·m
Fault signal relayYes
Overload protectionBuilt-in electronic overload protection
Protection functionBypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
By-pass signal relayYes
Overload signal relayYes
Ambient air temperatureOperation -25 ... +60 °C
Service factor percentage100 %
Object classification codeQ
Popular downloads (EPLAN data)9AAC185675_EPLAN
Signal indication faultRed
Integrated electronic overloadYes
Signal indication running rGreen
Connecting capacity supply circuitRigid 1 x 2.5
IDEA granular category code4740 >> Soft starter
Signal indication protectionYellow
Connecting capacity control circuitRigid 1 x 2.5 mm²
Popular downloads (Instructions and manuals)1SFC132428M0201
Popular downloads (Data sheet, technical information)1SFC132012C0201
Popular Downloads/Instructions and manuals (Part 2)1SFC132081M0201
Popular Downloads/Instructions and manuals (Part 3)1SFC132060M0201

Product details

The ABB 1SFA898120R7000 is a PSTX1050 soft starter with auto phase sequence detection, designed to ramp three-phase induction motors up and down smoothly, reducing mechanical shock and inrush current. Rated for 208 to 600 V AC at 50/60 Hz, it carries a UL/CSA horsepower rating of 400 Hp at 200-208 V AC three-phase. Built-in electronic overload protection eliminates the need for a separate overload relay, saving panel space and wiring.

Ramp and protection depth

Ramp time is adjustable from 1 to 120 seconds, with initial voltage during start configurable from 10 to 99%. Protection functions include locked rotor, earth fault, phase reversal, under/over voltage, current imbalance, and PT-100 connection for motor thermal monitoring. Warning outputs cover current imbalance, underload, electronic overload time-to-trip, faulty fan, locked rotor, and THD(U) among others.

Supports Modbus-RTU, Modbus-TCP, Ethernet/IP, EtherCAT, DeviceNet, CANopen, Profibus, Profinet, BACnet-IP, and BACnet-MSTP — covers nearly every industrial network in a single unit. Analog outputs provide 0-10 V, 0-20 mA, or 4-20 mA signals for external monitoring or trending. Dedicated run, fault, bypass, and overload signal relays are built in, plus a 24 V DC control circuit and a separate 100-250 V AC control supply for the logic.

RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863, classified as Business To Business WEEE Category 4 (Large Equipment).

Frequently asked questions

What is the function of 1SFA898120R7000?

Its primary function is auto phase sequence detection, ensuring the motor phase rotation matches the supply before the soft starter engages.

What is the ramp time range for this soft starter?

Ramp time is adjustable from 1 to 120 seconds, with initial voltage configurable from 10 to 99%.

What compliance documentation does ABB provide for 1SFA898120R7000?

RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863, WEEE Category 4 B2B. UL/CSA horsepower rating is documented at 400 Hp at 200-208 V AC.

MPN