Specifications

1SFA898208R7000 key specifications
ParameterValue
Terminal typeCable Clamp
Product main typePSTX85
Voltage208 ... 690 V AC
Initial voltage during start10 ... 99 %
Step down voltage special ramp100 ... 10 %
Rated control supply voltage100 ... 250 V AC
Rated control circuit voltage24 V DC
Technical UL (CSA, maximum operating voltage UL, CSA)Main Circuit 690 V
Current limit function1.5 ... 7.5 xle
Starting capacity at maximum rated current ie4xIe for 10s
Rated operational current - In-Line connection85 A
Rated operational current - inside delta connection147 A

All specifications

1SFA898208R7000 additional specifications
ParameterValue
Technical UL (CSA, horsepower rating UL, CSA)(200 ... 208 V AC) Three Phase 25 Hp
Rated operational power - In-Line connection(230 V) 22 kW
Rated operational power - inside delta connectionat 230 V 40 kW
Rated frequency50/60 Hz
IP ratingacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
ProtocolModbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Switch for inside delta connectionYes
Material compliance (SCIP)f3a0566c-5aad-4ac9-94d0-4c2d5492623c China
Popular downloads (CAD dimensional drawing)2CDC001079B0201
Material compliance (Toxic substances control act - TSCA)2CMT2023-006524
Material compliance (Conflict minerals reporting template)9AKK108467A5658
Technical UL (CSA, tightening torque UL, CSA)Main Circuit 70.8
FunctionAuto phase sequence detection
Ramp time1 ... 120 second [unit of time]
Analog outputs0...10 V, 0...20 mA, 4...20 mA
Warning detailsCurrent imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Run signal relayYes
Tightening torqueMain Circuit 8 N·m
Fault signal relayYes
Overload protectionBuilt-in electronic overload protection
Protection functionBypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
By-pass signal relayYes
Overload signal relayYes
Ambient air temperatureOperation -25 ... +60 °C
Service factor percentage100 %
Object classification codeQ
Popular downloads (EPLAN data)9AAC181164_EPLAN
Signal indication faultRed
Integrated electronic overloadYes
Connecting capacity main circuitHole Diameter 8.5 mm
Signal indication running rGreen
Connecting capacity supply circuitRigid 1 x 2.5
IDEA granular category code4740 >> Soft starter
Signal indication protectionYellow
Connecting capacity control circuitRigid 1 x 2.5 mm²
Popular downloads (Instructions and manuals)1SFC132428M0201
Popular downloads (Data sheet, technical information)1SFC132012C0201
Popular Downloads/Instructions and manuals (Part 2)1SFC132081M0201
Popular Downloads/Instructions and manuals (Part 3)1SFC132060M0201

Product details

The ABB 1SFA898208R7000 is a PSTX85 soft starter with built-in auto phase sequence detection — it verifies the incoming phase rotation before the motor starts, so a reversed-phase condition is caught at commissioning, not on a locked-rotor fault. The ramp time is adjustable from 1 to 120 seconds, which lets you tune the acceleration profile to the load inertia (conveyor, pump, fan).

Protection and control scope

The electronic overload is integrated — no separate overload relay needed. Protection covers current imbalance, underload, locked rotor, earth fault, phase reversal, over/under voltage, and ground fault. It also accepts PTC and PT-100 inputs for motor thermal monitoring. The analog outputs (0-10 V, 0-20 mA, 4-20 mA) can feed motor current or voltage signals to a PLC or drive controller.

Communication and integration

This soft starter speaks Modbus-RTU, Modbus-TCP, Ethernet/IP, EtherCAT, DeviceNet, CANopen, Profibus, Profinet, BACnet-IP, and BACnet-MSTP — it fits into nearly any fieldbus architecture without a gateway. The control supply is 100-250 V AC; the control circuit runs on 24 V DC. The main circuit terminals are cable-clamp type with an 8.5 mm hole diameter and 8 N·m tightening torque.

Frequently asked questions

What is the ramp time range for 1SFA898208R7000?

The ramp time is adjustable from 1 to 120 seconds, allowing you to match the acceleration profile to the load.

What communication protocols does this soft starter support?

It supports Modbus-RTU, Modbus-TCP, Ethernet/IP, EtherCAT, DeviceNet, CANopen, Profibus, Profinet, BACnet-IP, and BACnet-MSTP.

Where can I buy 1SFA898208R7000 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What compliance documentation does ABB provide for 1SFA898208R7000?

The part complies with EU RoHS Directive 2011/65/EU and Amendment 2015/863. WEEE category is small equipment (B2B).

MPN
1SFA898208R7000