ABB 1SVR011715R1200 — General Purpose Relays

ABB 1SVR011715R1200 CC-E I/I Signal Converter, 0-20 mA Input

MPN1SVR011715R1200

ABB CC-E I/I Signal Converter, singlef., 1SVR011715R1200, 0...20 mA input, 4...20 mA output, ± 0.5 % accuracy, 200 µs response time, 24 V DC, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

1SVR011715R1200 — Specifications
ParameterValue
Weight0.084 Kg
Accuracy± 0.5 % of full-scale
Input signal0 ... 20 mA
Product typeCC-E I/I Signal converter, singlef.
Output signal4 ... 20 mA
Response time200 µs
Supply voltage24 V DC
IP ratingIP20
Dimension (lxwxh)10.7 x 2.25 x 7.5 cm
Ambient temperature range0...+60 °C / -20...+80 °C

Product details

The ABB 1SVR011715R1200 is a CC-E I/I signal converter that takes a 0...20 mA input and outputs a 4...20 mA signal. This single-function device is what you reach for when a PLC analog input expects a live-zero 4-20 mA loop but your transmitter puts out a 0-20 mA signal — or when you need galvanic isolation between field wiring and the control card. The ±0.5 % of full-scale accuracy means the output tracks the input within 0.1 mA at 20 mA span, tight enough for most process monitoring and control loops without a separate calibration trimmer in the signal path.

Response time and loop dynamics

With a 200 µs response time, this converter keeps up with fast-changing signals — pressure spikes on a hydraulic press, flow surges in a filling line, or a valve positioner that needs to see the setpoint update within a millisecond. That speed also means it won't add a noticeable lag in a cascade loop. The 24 V DC supply powers the internal electronics and the output loop; watch the total loop resistance if you're driving a long cable run or multiple receivers. The IP20 housing means this goes inside an enclosure — not on the machine frame exposed to washdown or dust.

Frequently asked questions

What is the accuracy of this signal converter?

The accuracy is ±0.5 % of full-scale. On a 4-20 mA output, full-scale is 16 mA, so the output error is within ±0.08 mA — tight enough for most process control applications without needing a field calibration.

What is the response time of the 1SVR011715R1200?

The response time is 200 µs. That means the output reaches its final value within 0.2 milliseconds of an input step change — fast enough for pressure, flow, or position control loops.

What is the input and output signal range?

The input accepts 0...20 mA and the output delivers 4...20 mA. This is a single-function I/I converter — no field-configurable jumpers for voltage or different ranges.

MPN
1SVR011715R1200