Skip to main content
ABB 1SVR040006R0100 — General Purpose Relays

ABB 1SVR040006R0100 CC-U/I Universal Signal Converter, ±0.5%

MPN1SVR040006R0100

ABB 1SVR040006R0100, CC-U/I Universal signal converter, Current RMS input 0...1 A / 0...5 A, output 0...±55 mA / 0...±11 V, accuracy ±0.5 % of full-scale.

$190.50 – $497.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

1SVR040006R0100 — Specifications
ParameterValue
Weight0.128 Kg
Accuracy±0.5 % of full-scale
Input signalCurrent RMS values 0 ... 1 A / 0 ... 5 A
Product typeCC-U/I Universal signal converter
Output signal0 ... ± 55 mA / 0 ... .± 11V
Response time150 ms
Dimension (lxwxh)12.0 x 2.25 x 10.5 cm
Rated supply voltage24-48 V DC
Ambient temperature range-20...+60 °C / -40...+80 °C

Product details

The ABB 1SVR040006R0100 is a CC-U/I universal signal converter that takes a current RMS input — either 0...1 A or 0...5 A — and outputs a proportional bipolar signal of 0...±55 mA or 0...±11 V. The ±0.5 % of full-scale accuracy means that at a 5 A input, the error stays under 25 mA; that's tight enough for most panel-level monitoring and control loops where you're feeding a PLC analog input or a drive's analog reference. The 150 ms response time is the settling time to 90 % of final value — fine for process signals like pump discharge pressure or conveyor speed feedback, but too slow for fast fault detection on a servo axis.

Universal signal converters like this one sit between a field transducer — say a current transformer on a motor feeder or a shunt on a DC drive — and the control system. They isolate, scale, and linearize the raw signal so a PLC analog input card sees a clean voltage or current range. Common on motor control centers, pump skids, and power-monitoring panels where you need to bring a CT secondary (1 A or 5 A) into a 0-10 V or 4-20 mA loop.

Frequently asked questions

What is the input signal range for this converter?

It accepts current RMS values of 0...1 A or 0...5 A, selectable per the wiring or configuration.

What output signal does it provide?

The output is 0...±55 mA or 0...±11 V, giving a bipolar signal that can represent forward/reverse or charge/discharge in a process loop.

What is the accuracy of this signal converter?

Accuracy is ±0.5 % of full-scale. For a 5 A input, that means the reading error stays under 25 mA.

What supply voltage does it need?

It requires a 24-48 V DC supply, compatible with standard 24 V control power or a 48 V DC bus.

MPN
1SVR040006R0100