ABB 266HRHSRRB1E1L1B6H1 + S26RRHE6SFLM3AESNNN, Gauge Pressure Transmitter with Remote Seal + Rotating Flange Diaphragm Seal (Flush) Ring Joint, Integral LCD, ATEX Ex ia IIC T6, 4-20 mA HART, Inconel 625 diaphragm, ASME CL 2500 / 2 in.

$2,784.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

266HRHSRRB1E1L1B6H1 + S26RRHE6SFLM3AESNNN — Measurement
ParameterValue
Sensor span limitsS
266HRHSRRB1E1L1B6H1 + S26RRHE6SFLM3AESNNN — Communication & Output
ParameterValue
Output / additional options1 = HART digital communication and 4 to 20 mA
Integral displayL1 = Digital LCD integral display
266HRHSRRB1E1L1B6H1 + S26RRHE6SFLM3AESNNN — Wetted Materials & Process Connection
ParameterValue
Process connectionR = Remote seal (except button type)
Diaphragm material & fill fluidR
266HRHSRRB1E1L1B6H1 + S26RRHE6SFLM3AESNNN — Mechanical & Enclosure
ParameterValue
Housing material & electrical connectionB
Mounting bracketB6 = For pipe/wall mounting - Carbon steel
266HRHSRRB1E1L1B6H1 + S26RRHE6SFLM3AESNNN — Environmental & Hazardous Area
ParameterValue
Hazardous area certificationsE1 = ATEX Intrinsic Safety II 1 G and II 1/2 G Ex ia IIC T6; II 1 D Ex iaD 20 T 95 °C and II 1/2D Ex iaD 21 T95 °C
266HRHSRRB1E1L1B6H1 + S26RRHE6SFLM3AESNNN — Identification
ParameterValue
Product typeGauge Pressure Transmitter with Remote Seal + Rotating Flange Diaphragm Seal (Flush) Ring Joint

Product details

Hazardous-Area Pressure Transmitter for High-Pressure Service

The ABB 266HRHSRRB1E1L1B6H1 + S26RRHE6SFLM3AESNNN is a gauge pressure transmitter configured with a remote seal and rotating flange diaphragm seal — a flush-mount assembly for high-pressure, high-temperature process connections where direct mounting is impractical. The ATEX Intrinsic Safety certification (: II 1 G and II 1/2 G Ex ia IIC T6; II 1 D Ex iaD 20 T 95 °C and II 1/2D Ex iaD 21 T95 °C) confirms it for Zone 0/1 gas and Zone 20/21 dust atmospheres, per IEC 60079-14 installation rules. The 4-20 mA output with HART digital communication allows remote configuration and diagnostics over a standard twisted pair — essential for offshore or refinery loops where loop-powered devices must pass through a safety barrier.

Flange, Diaphragm, and Fill Fluid — What the Specs Mean for Fit

The mounting flange is ASME CL 2500 / 2 in. — a 2500-pound class ring-joint flange for extreme pressures. The diaphragm material is Inconel 625, selected for corrosion resistance in sour-gas or chloride-laden environments. Fill fluid is silicone oil DC200 10 cSt, a standard high-temperature fill. The capillary length is 3 m (10 ft) with AISI 316L stainless steel armour protecting the capillary bundle from mechanical damage. The flush diaphragm with ring-joint seal surface finish eliminates dead-leg cavities — important for polymerizing, viscous, or sanitary media where a conventional impulse line would plug.

Integral Display and Material Traceability

The L1 option adds a digital LCD integral display for local pressure readout and HART loop diagnostics — useful during commissioning when the DCS is not yet live. Material traceability per EN 10204–2.1 is included for the process-wetted parts, satisfying the documentation requirements of NACE MR0175 / ISO 15156 applications.

Frequently asked questions

Where can I buy 266HRHSRRB1E1L1B6H1 + S26RRHE6SFLM3AESNNN and what is the price?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What hazardous-area certifications does this transmitter carry?

ATEX Intrinsic Safety: II 1 G and II 1/2 G Ex ia IIC T6 for gas; II 1 D Ex iaD 20 T 95 °C and II 1/2D Ex iaD 21 T95 °C for dust. Suitable for Zone 0/1 gas and Zone 20/21 dust atmospheres.

What is the output signal and communication protocol?

4-20 mA analog with HART digital communication. Loop-powered; configuration and diagnostics via HART modem or communicator.

MPN