ABB 266MSTLCSB3B1E1L1B1C1M5 — Differential Pressure Transmitters

ABB 266MSTLCSB3B1E1L1B1C1M5 Differential Pressure

MPN266MSTLCSB3B1E1L1B1C1M5

ABB 266MSTLCSB3B1E1L1B1C1M5 Differential Pressure Transmitter, 266MST series, HART digital communication and 4 to 20 mA output, sensor span 2.5 to 250 kPa, maximum working pressure 160 bar, ATEX Intrinsic Safety Ex ia, integral LCD display.

$3,552.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

266MSTLCSB3B1E1L1B1C1M5 — Identification
ParameterValue
Product type266MST Differential Pressure Transmitters
266MSTLCSB3B1E1L1B1C1M5 — Electrical & Output
ParameterValue
Output1 - HART digital communication and 4 to 20 mA
Integral LCD displayL1 - With integral LCD display
266MSTLCSB3B1E1L1B1C1M5 — Mechanical
ParameterValue
Weight4.35 Kg

Product details

Active production, built for process lines

The 266MSTLCSB3B1E1L1B1C1M5: The transmitter carries ATEX Intrinsic Safety Ex ia certification, which means it can be wired into a hazardous-area loop without a separate safety barrier as long as the associated equipment is also Ex ia rated.

Wetted materials and chemical compatibility

The diaphragm is AISI 316L SST (1.4435) with silicone oil fill, and the process flanges/adapters are AISI 316L SST (1.4404/1.4408) with a 1/2-14 NPT female horizontal connection — all NACE compliant, so it fits sour-gas service where sulfide stress cracking is a concern. Bolts are AISI 316 SST (NACE, not exposed to H2S) with Viton gaskets suitable for oxygen applications, rated to 41 MPa / 410 bar / 5945 psi — this combination resists a broad range of process chemicals, but the Viton limits the upper temperature to about 200 °C continuous.

Span, pressure, and output

Sensor span limits are 2.5 to 250 kPa (25 to 2500 mbar, 10 to 1000 inH2O) — a wide turndown that lets one transmitter cover multiple DP ranges on a distillation column or filter differential without re-ranging the hardware. Maximum working pressure is 16 MPa / 160 bar / 2320 psi, so it handles line pressures typical of refinery and chemical process headers without exceeding the cell rating. Output is HART digital communication superimposed on the 4-20 mA analog signal — the HART protocol lets you read the primary variable and up to three additional process variables digitally over the same two wires, and you can configure the transmitter remotely from the control room.

Mounting, housing, and display

The housing is aluminum alloy (barrel type) with M20 x 1.5 electrical connection — standard for European hazardous-area installations, and the barrel shape provides a clean cable entry point for the gland. Mounting bracket is carbon steel for pipe mounting, so it straps directly to a 2-inch vertical or horizontal pipe in the field; note that this bracket is not suitable for aluminum housings due to galvanic corrosion risk. Integral LCD display is fitted — local readout of the process variable without needing a handheld communicator, which saves time during commissioning and loop checks.

MPN
266MSTLCSB3B1E1L1B1C1M5