Skip to main content
ABB 2CCF004155R0001 — Residual Current Breakers (RCCB/RCBO)

ABB 2CCF004155R0001 Motor Protection Circuit Breaker, 2.5A,

MPN2CCF004155R0001

ABB, motor protection circuit breaker, 2CCF004155R0001, 3-pole, 1.6–2.5 A overload range, Class 10, 400 V, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

2CCF004155R0001 — Mechanical
ParameterValue
Width94.5 mm
Height90 mm
Depth54 mm
2CCF004155R0001 — Other specifications
ParameterValue
Poles3
Tripping classClass 10
IP ratingIP 20
Overload release max.2.5 A
Overload release min.1.6 A
Rated operating current2.5
Service life, mechanical100 000 cycles
Operating temperature max.50 °C
Operating temperature min.-25 °C
Cross-section, flexible max.6 mm²
Cross-section, flexible min.0.75 mm²
Rated operating voltage max.400 V

Product details

The ABB 2CCF004155R0001 is a 3-pole motor protection circuit breaker sized for the 1.6–2.5 A overload range. Class 10 tripping means it clears a stalled rotor fast enough to protect standard IEC induction motors before the winding insulation takes heat damage — that's the trip class you want for pumps, fans, and compressors on a general-purpose line. Rated operating voltage maxes out at 400 V, which covers most 230/400 V three-phase panels.

IP20 finger-safe housing means it belongs inside a panel, not out on the wet floor. The 54 mm depth and 94.5 mm width fit a standard DIN-rail footprint; you can stack it next to a contactor without eating into the next row. Terminals accept 0.75–6 mm² flexible copper — fine for the motor leads on a sub-2.5 A circuit.

Rated for 100,000 mechanical cycles — that's a long service life for a manual motor starter in a panel that sees regular switching.

Frequently asked questions

Where can I buy the 2CCF004155R0001 and get a price?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the overload range on this motor circuit breaker?

The overload release range is 1.6 A minimum to 2.5 A maximum. That means the thermal adjustment dial covers motors drawing between those full-load amps, with Class 10 trip characteristics.

What is the closest alternative to the 2CCF004155R0001?

Within the same ABB manual motor starter family, the closest peer would share the same 3-pole frame and Class 10 trip curve but with a different overload range. The deciding factor is your motor's full-load current — this unit covers 1.6–2.5 A, so a peer with an adjacent range (e.g., 2.5–4 A) would be the next step up. No pin-compatible drop-in exists outside that range.

MPN
2CCF004155R0001