Skip to main content
ABB 2CCS451001R0164 — 1-Pole MCB (DIN Rail)

ABB 2CCS451001R0164 MCB, C-Curve 16A, 1-Pole, 6kA

MPN2CCS451001R0164

ABB miniature circuit breaker, C-curve, 16 A, 1 pole, 440 V, 6 kA breaking capacity, IP20, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

2CCS451001R0164 — Electrical & Protection
ParameterValue
Overvoltage categoryIII
2CCS451001R0164 — Mounting & Connection
ParameterValue
Width69 mm
Height89 mm
Depth94.5 mm
2CCS451001R0164 — Other specifications
ParameterValue
Poles1
IP ratingIP20
MountingDIN Rail Mount
Current16 A
Terminal contact typeScrew
Voltage440 V
Tripping characteristicsC
Rated Short-Circuit breaking capacity icn6 kA
Rated Short-Circuit breaking capacity icu6 kA

Product details

What bolts in for a 16 A lighting or socket circuit

The ABB 2CCS451001R0164 is a 1-pole miniature circuit breaker, C-curve, rated 16 A at 440 V with 6 kA breaking capacity. It's the go-to for protecting lighting circuits, socket outlets, and small appliance feeds in distribution boards. Rated insulation voltage of 440 V covers standard three-phase 230/400 V systems. Overvoltage category III means it's rated for fixed-installation duty — distribution panels, sub-mains, not just final sub-circuits.

DIN rail fit and panel space

Single-pole width means it takes one module space — roughly 17.5 mm — so it packs tight in a crowded enclosure. Depth of 94.5 mm leaves room in shallow back-boxes; height of 89 mm clears most gland plates. IP20 finger-safe terminals with screw clamps. Accepts solid or stranded copper up to 25 mm². Strip length 10 mm, torque to 2.5 Nm — standard practice for panel wiremen.

Frequently asked questions

What is the ABB S401M-C16 equivalent replacement for 2CCS451001R0164?

Buyers facing EOL or allocation need a verified pin-compatible or form-fit-function alternate to avoid redesigns.

Is the 2CCS451001R0164 MCB obsolete or still in production, and is there a last-time-buy notice?

LTB managers and spares planners must lock supply or qualify alternates before allocation causes downtime.

Can a 16A 6kA C-curve MCB be used as upstream protection for a VFD input?

Drive input inrush frequently trips C-curve instantaneous bands; engineers need a clear guidance vs D-curve selection.

What wire gauge and torque specs apply to the ABB S401M-C16 terminals?

Panel builders need exact lug ratings for UL/IEC compliance and torque to pass inspection on the first build.

What is the 6kA interrupting rating and trip curve (Icn/Ics) for the 2CCS451001R0164 at 440V?

Power-distribution engineers must verify kAIC and selectivity against upstream/downstream devices in coordination studies.

Where can a single unit of 2CCS451001R0164 be sourced with trace documentation?

Hobbyists and brokers want small-quantity, traceable stock and must verify authenticity on allocated S400 parts.

MPN
2CCS451001R0164