ABB 2CCS471001R0277 — 1-Pole MCB (DIN Rail)

ABB 2CCS471001R0277 1-Pole MCB, K Curve, 2 A, 10 kA

MPN2CCS471001R0277

ABB 2CCS471001R0277 1-Pole MCB (DIN Rail), K tripping characteristic, 2 A rated current, 440 V rated insulation voltage, 10 kA Icn / 50 kA Icu, IP20, screw terminals.

$44.48 – $50.42Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

2CCS471001R0277 — Electrical & Protection
ParameterValue
Overvoltage categoryIII
2CCS471001R0277 — Mounting & Connection
ParameterValue
Width69 mm
Height89 mm
Depth94.5 mm
2CCS471001R0277 — Other specifications
ParameterValue
Poles1
IP ratingIP20
MountingDIN Rail Mount
Current2 A
Terminal contact typeScrew
Voltage440 V
Tripping characteristicsK
Rated Short-Circuit breaking capacity icn10 kA
Rated Short-Circuit breaking capacity icu50 kA

Product details

K-curve 2 A MCB for inductive and motor-circuit protection

The ABB 2CCS471001R0277 is a 1-pole miniature circuit breaker with a K tripping characteristic, rated at 2 A. The K curve is designed for inductive loads and motor circuits where inrush currents are higher than resistive loads — it tolerates short-duration surges up to 10–14 times the rated current before tripping, so it won't nuisance-trip on a motor start or transformer energisation. Rated insulation voltage is 440 V, with a short-circuit breaking capacity of 10 kA per IEC/EN 60898 (Icn) and 50 kA per IEC/EN 60947-2 (Icu). The 50 kA Icu rating means the breaker can safely interrupt a fault up to that level once and remain functional — a useful margin in high-fault-current panels near large transformers.

DIN-rail fit and panel integration

Snaps onto standard 35 mm DIN rail per EN 60715. The 1-pole width is 17.5 mm (one modular unit), with dimensions 89 mm height, 69 mm width, and 94.5 mm depth — fits standard distribution boards and sub-panels without crowding adjacent breakers. Screw-type terminals accept copper conductors up to 25 mm². Overvoltage category III means it's rated for fixed installation downstream of the main distribution board — typical for branch-circuit protection in commercial and industrial panels.

Frequently asked questions

How can I order the ABB 2CCS471001R0277 or check availability?

No stock-holding claim is made on this listing.

What does the K tripping characteristic mean for this 2 A breaker?

The K curve trips at 10–14 times the rated current (20–28 A) for short-circuit events, with a thermal delay for sustained overloads. This suits inductive loads like small motors, solenoids, and transformers that draw a high inrush on start-up — the breaker won't nuisance-trip on the surge but still protects the cable against sustained overload.

What is the difference between Icn and Icu on this MCB?

Icn (10 kA) is the rated short-circuit breaking capacity per the domestic-standard EN 60898 — the breaker can clear a fault at that level and is expected to remain serviceable. Icu (50 kA) is the ultimate breaking capacity per the industrial-standard IEC 60947-2 — the breaker can safely interrupt a fault up to 50 kA once, after which it may need replacement. The higher Icu rating gives margin in high-fault-current industrial panels.

MPN
2CCS471001R0277