Skip to main content
ABB 2CDS251001R0065 — 1-Pole MCB (DIN Rail)

ABB 2CDS251001R0065 1-Pole MCB, B Curve, 6A, 6 kA

MPN2CDS251001R0065

ABB, 1-Pole MCB (DIN Rail), System pro M compact S200 series, 2CDS251001R0065, B curve, 6 A, 6 kA Icn, 20 kA Icu, 440 V rated insulation voltage, DIN rail mount.

$3.77Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

2CDS251001R0065 — Electrical & Protection
ParameterValue
Overvoltage categoryIII
2CDS251001R0065 — Mounting & Connection
ParameterValue
Width17.5 mm
Height88 mm
Depth69 mm
2CDS251001R0065 — Other specifications
ParameterValue
Poles1
IP ratingIP20;IP40
MountingDIN Rail Mount
Current6 A
Terminal contact typeBi-Directional Cylinder Lift
Voltage440 V
Tripping characteristicsB
Tightening torque - Screw-Type max.2.8 Nm
Rated Short-Circuit breaking capacity icn6 kA
Rated Short-Circuit breaking capacity icu20 kA

Product details

What the B-curve 6 A rating means for your panel

The 2CDS251001R0065 is an ABB 1-pole miniature circuit breaker from the System pro M compact S200 series, rated 6 A with a B tripping characteristic. The B curve means the magnetic trip activates at 3-5 times rated current — it clears fast on a short-circuit but tolerates the inrush of resistive or lightly inductive loads without nuisance tripping. That makes it a natural fit for general-purpose distribution circuits, lighting panels, and control transformers in a DIN-rail enclosure. The rated short-circuit breaking capacity Icn is 6 kA per IEC 60898, while the ultimate breaking capacity Icu hits 20 kA per IEC 60947-2 — the higher figure applies when the breaker is part of a motor-circuit or industrial panel covered under the 60947 standard. The rated insulation voltage sits at 440 V, and the overvoltage category is III, meaning it is designed for fixed-installation panels where transient overvoltages from the mains supply are expected.

Mounting, termination, and environmental sealing

The breaker snaps onto a DIN rail and occupies 17.5 mm width per pole — standard 1-module footprint. The bi-directional cylinder-lift terminal accepts copper conductors up to the rated cross-section and requires a tightening torque of 2.8 Nm max. Depth is 69 mm, height 88 mm, so it clears most standard distribution board covers. Ingress protection is IP20 on the front (finger-safe) and IP40 inside the enclosure — the IP40 rating means the installed breaker withstands dust ingress typical of a closed panel, but it is not rated for washdown or outdoor exposure without a secondary enclosure.

MPN