Skip to main content
ABB 2CDS251103R0064

ABB 2CDS251103R0064 2-Pole MCB, C-Curve, 6A, 6kA Icn

MPN 2CDS251103R0064

ABB 2CDS251103R0064, 2-Pole MCB (DIN Rail), C-curve, 6 A, 440 V rated insulation, 6 kA Icn / 20 kA Icu, IP20/IP40, DIN rail mount, 35 mm width, 88 mm height, 69 mm depth.

$10.19 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

2CDS251103R0064 specifications
ParameterValue
Insulation voltage ui440 V
Current6 A
Poles2
IP ratingIP20 / IP40
MountingDIN Rail
Depth69 mm
Width35 mm
Height88 mm

Product details

DIN rail form factor and panel fit

The 2CDS251103R0064: This 2-pole MCB occupies a standard 35 mm width on the DIN rail, with an 88 mm height and 69 mm depth — the envelope fits a standard distribution board cutout without crowding adjacent ways. The IP20 rating on the front face means it is protected against finger contact; the IP40 rating on the enclosure body keeps out tools and small wires, which is the norm for enclosed panel mounting.

Breaking capacity and trip coordination

Rated short-circuit breaking capacity Icn is 6 kA per IEC 60898 — this is the service breaking capacity for a domestic or light commercial distribution board. The ultimate breaking capacity Icu is 20 kA per IEC 60947-2, meaning the MCB can safely interrupt a 20 kA fault once without needing replacement, which is relevant when the device is applied in an industrial panel with higher prospective fault current. The C-trip characteristic means the magnetic release trips at 5 to 10 times rated current — suited for circuits with moderate inrush, such as small motor loads or lighting banks with capacitive drivers.

Installation class and terminal design

Overvoltage category III means this MCB is rated for fixed installation downstream of the main distribution board — it can handle transient overvoltages typical of building wiring without additional surge protection. Rated insulation voltage is 440 V, which covers 230/400 V three-phase systems with margin. The bi-directional cylinder-lift terminal accepts both solid and stranded copper conductors up to the rated cross-section, with a max tightening torque of 2.8 Nm.

MPN
2CDS251103R0064