ABB 2CDS271103R0164 — 2-Pole MCB (DIN Rail)

ABB 2CDS271103R0164 MCB, 2-Pole C-Curve 16 A, 10 kA

MPN2CDS271103R0164

ABB 2CDS271103R0164 miniature circuit breaker, 2-pole, C-curve, 16 A, 440 V, 10 kA Icn, 25 kA Icu, DIN rail mount, IP20/IP40.

$86.03 – $98.57Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

2CDS271103R0164 — Protection
ParameterValue
Overvoltage categoryIII
2CDS271103R0164 — Mechanical
ParameterValue
Width35 mm
Height88 mm
Depth69 mm
2CDS271103R0164 — Other specifications
ParameterValue
Poles2
IP ratingIP20;IP40
MountingDIN Rail Mount
Current16 A
Terminal contact typeBi-Directional Cylinder Lift
Voltage440 V
Tripping characteristicsC
Tightening torque - Screw-Type max.2.8 Nm
Rated Short-Circuit breaking capacity icn10 kA
Rated Short-Circuit breaking capacity icu25 kA

Product details

What this MCB is and what the ratings mean for your panel

The ABB 2CDS271103R0164 is a 2-pole miniature circuit breaker with a C tripping characteristic, rated 16 A continuous current and 440 V insulation voltage. The C-curve means it trips between 5 and 10 times rated current — designed for moderate inrush loads like small motors, transformers, and lighting circuits where a B-curve would nuisance-trip on startup, but the fault clearance is still fast enough for branch protection. Rated short-circuit breaking capacity is 10 kA per IEC 60898 (Icn) and 25 kA per IEC 60947-2 (Icu). The Icn figure governs domestic/commercial distribution boards; the higher Icu applies when the breaker is used in industrial panels per the product standard. Either way, it clears a hard fault up to that level without welding the contacts or cascading upstream. Overvoltage category III means it is rated for fixed installation downstream of the main distribution board — not for plug-in equipment. Mounts on standard DIN rail (35 mm per EN 60715). The 35 mm width (2 module spaces) fits the standard cutout in any DIN-rail enclosure. IP20 on the terminals, IP40 on the front face; suitable for clean, dry indoor panels where no washdown or dust ingress is expected.

Frequently asked questions

What is the breaking capacity of this MCB?

Rated short-circuit breaking capacity Icn is 10 kA per IEC 60898; Icu is 25 kA per IEC 60947-2.

What is the tripping curve and what does it mean?

C-curve trips at 5 to 10 times rated current. It is suited for loads with moderate inrush like small motors, transformers, and capacitor banks where a B-curve would cause nuisance trips.

What are the mounting dimensions?

Width 35 mm (2 module spaces), height 88 mm, depth 69 mm. DIN rail mount per EN 60715.