ABB 2CDS271337R0337 — 1-Pole MCB (DIN Rail)

ABB 2CDS271337R0337 1-Pole MCB, K Curve, 4 A

MPN2CDS271337R0337

ABB 1-Pole MCB (DIN Rail), K tripping curve, 4 A rated current, 440 V rated insulation voltage, 11.2 kA Icn, IP20/IP40, DIN Rail Mount.

$64.72 – $69.11Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

2CDS271337R0337 — Electrical & Protection
ParameterValue
Overvoltage categoryIII
2CDS271337R0337 — Mounting & Connection
ParameterValue
Width17.5 mm
Height111 mm
Depth69 mm
2CDS271337R0337 — Other specifications
ParameterValue
Poles1
IP ratingIP20;IP40
MountingDIN Rail Mount
Current4 A
Terminal contact typeBi-Directional Cylinder Lift
Voltage440 V
Tripping characteristicsK
Tightening torque - Screw-Type max.2.8 Nm
Rated Short-Circuit breaking capacity icn11.2 kA
Rated Short-Circuit breaking capacity icu15 kA

Product details

K-curve 4 A — inductive-load branch protection

The ABB 2CDS271337R0337 is a 1-pole miniature circuit breaker with K tripping characteristics, rated 4 A continuous current and 440 V rated insulation voltage. The K curve means the magnetic trip threshold sits at 8–12× In — designed to ride through the inrush of transformers, solenoid valves, and motor starters without nuisance tripping on the magnetizing surge. Rated short-circuit breaking capacity Icn is 11.2 kA per the standard, with an ultimate Icu of 15 kA — the breaker clears a fault up to that level without welding the contacts, then remains serviceable. Overvoltage category III rating confirms it is rated for fixed-installation downstream of the service entrance, not just outlet-level protection.

DIN-rail footprint and panel integration

Snaps onto standard 35 mm DIN rail per EN 60715. The 17.5 mm width (1 module) and 69 mm depth fit a single-pole position in any distribution board or control panel — no extra clearance needed beyond the standard busbar comb spacing. Height is 111 mm, matching the ABB S200 series envelope. IP20 on the front face (finger-safe terminals with the breaker in the ON position), IP40 on the sides (tool-proof against wire probes). The bi-directional cylinder-lift terminal accepts both copper and aluminium conductors up to the rated cross-section; tightening torque max 2.8 Nm ensures the connection holds through thermal cycling.

Frequently asked questions

What does the K tripping curve mean on the ABB 2CDS271337R0337?

The K curve trips magnetically at 8–12 times the rated current (4 A), so the magnetic trip threshold is 32–48 A. This is higher than a B or C curve — it is chosen for circuits with inductive inrush like transformers, solenoid banks, or small motor starters where the start surge would otherwise trip a standard breaker.

What is the difference between Icn and Icu on this MCB?

Icn (11.2 kA) is the rated short-circuit breaking capacity per the product standard — the breaker must clear a fault at that level and still be functional afterward. Icu (15 kA) is the ultimate breaking capacity: it clears the fault once but may not be reusable. For branch-circuit protection, Icn is the design figure; Icu is the safety margin.