Drive selection memo — 3ABD0000058125
LV AC machinery drive module delivering 2.2 kW at 5.6 A on a 380–480 V three-phase supply. Frame size R1 and wall-mounting fit a 2.2 kW motor on conveyor, pump, or fan duty. The 47.5–63 Hz input frequency range covers 50 Hz and 60 Hz grids globally, so no derating needed when moving between line frequencies.
Efficiency and protection
Rated IE2 efficiency meets the minimum standard for most industrial motor-drive applications across Europe and aligned markets. IP20 enclosure (NEMA Open Type) means it belongs inside a clean, dry cabinet — not on the machine frame in a washdown zone.