The 3ABD00015753-D: Standby loss of 17 W is the heat the drive dissipates when the motor is stopped but the DC bus is live — relevant for panel thermal calculations in cabinets with limited ventilation. The IE2 efficiency class means this drive meets the European efficiency level for motor systems.
Rated for 40 °C ambient without derating, which is typical for ventilated indoor enclosures. Wall-mount installation is the intended method; the frame size R4 determines the drilling template and clearance for the gland plate.