Skip to main content
ABB 3ABD00039252-D — AC Drive (VFD) 600V

ABB 3ABD00039252-D ACS880-01 drive, 160 kW, 174 A, IP21

MPN3ABD00039252-D
Active

ABB ACS880-01 series, wall-mounted LV AC drive, 3-phase, 525-690 V input, 160 kW / 174 A normal use, IP21, NEMA Type 1, IE2, frame size R8.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3ABD00039252-D — Identification
ParameterValue
Frame sizeR8
3ABD00039252-D — Electrical (input)
ParameterValue
Input voltage range525 ... 690 V
Number of phases3-phase
Frequency range47.5 ... 63 Hz
3ABD00039252-D — Output / Performance
ParameterValue
Output power, normal duty160 kW
Output power, heavy duty132 kW
Output power, light overload160 kW
Output current, normal duty174 A
Output current, heavy duty142 A
Output current, light overload165 A
Efficiency level (IE class)IE2
3ABD00039252-D — Mechanical
ParameterValue
Mounting typeWall-mounted
NEMA enclosure typeType1
3ABD00039252-D — Environmental
ParameterValue
Degree of protection (IEC, IP)IP21

Product details

The ABB 3ABD00039252-D is a wall-mounted single drive rated for 160 kW normal-use output at 174 A, with a heavy-duty rating of 132 kW at 142 A and a light-overload rating of 160 kW at 165 A. It accepts 525-690 V three-phase input, runs on 47.5-63 Hz mains, and carries IP21 protection in a NEMA Type 1 enclosure. Frame size is R8, and the efficiency class is IE2.

For frequent starts or high breakaway torque, the heavy-duty curve (142 A) governs.

This class of drive is installed in industrial control panels for variable-speed control of three-phase induction motors — conveyors, pumps, fans, compressors. The wall-mounted form factor and IP21 rating suit indoor, clean-environment installations where the drive is separated from washdown or dust zones.

Frequently asked questions

What is the frame size of this drive?

The listed frame size is R8, which determines the physical mounting footprint and the available options slot configuration.

What are the key current ratings?

Normal-use output current is 174 A, heavy-duty is 142 A, and light-overload is 165 A. The normal-use rating is the continuous figure for standard motor loads.

MPN
3ABD00039252-D