Skip to main content
ABB 3ABD00039537-D — AC Drive (VFD) 600V

ABB 3ABD00039537-D ACS880-04 Drive Module, 630 kW, 650 A, Fr

MPN3ABD00039537-D
Active

ABB ACS880-04, LV AC industrial single drive module, 3-phase, 525–690 V input, 630 kW / 650 A normal use, frame R11, IP20, open type.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3ABD00039537-D — Identification
ParameterValue
Frame sizeR11
3ABD00039537-D — Electrical (input)
ParameterValue
Input voltage range525 ... 690 V
Number of phases3-phase
Frequency range47.5 ... 63 Hz
3ABD00039537-D — Output / Performance
ParameterValue
Output power, normal duty630 kW
Output power, heavy duty560 kW
Output power, light overload630 kW
Output current, normal duty650 A
Output current, heavy duty571 A
Output current, light overload630 A
3ABD00039537-D — Mechanical
ParameterValue
Mounting typeModule
NEMA enclosure typeOpen Type
3ABD00039537-D — Environmental
ParameterValue
Degree of protection (IEC, IP)IP20

Product details

630 kW drive module for 525–690 V three-phase lines

The ABB 3ABD00039537-D is an LV AC industrial single drive module rated for 630 kW normal-use output power at 650 A, with a 525–690 V three-phase input spanning 47.5 to 63 Hz. It carries heavy-duty ratings of 560 kW / 571 A and light-overload ratings of 630 kW / 630 A.

The normal-use rating (630 kW / 650 A) covers continuous constant-torque applications like conveyors and screw feeders. The heavy-duty figure (560 kW / 571 A) applies when the motor sees 150% overload for 60 seconds — typical for crushers, extruders, or punch presses. The light-overload rating (630 kW / 630 A) matches variable-torque loads such as centrifugal pumps and fans where peak demand stays under 110%. Choosing the wrong duty class risks nuisance tripping or undersized cabling; the 650 A normal-use current sets the branch-circuit conductor and fuse sizing.

Frame R11 determines the mounting footprint and bus-bar layout; verify the cabinet depth and gland-plate clearance before laying out the panel. The 525–690 V input range suits 600 V class北美 systems and 690 V European industrial grids; the 47.5–63 Hz frequency tolerance covers 50 Hz and 60 Hz supplies without derating.

Frequently asked questions

What are the key ratings for 3ABD00039537-D?

Normal-use output is 630 kW at 650 A; heavy-duty is 560 kW at 571 A; light-overload is 630 kW at 630 A. Input is 525–690 V three-phase, 47.5–63 Hz. Frame size is R11 with IP20 protection.

MPN
3ABD00039537-D