ABB 3ABD00039814-D — AC Drive (VFD) 480V

3ABD00039814-D ABB ACS530-01-106A-4 55kW Drive, Frame R5, 10

MPN3ABD00039814-D
Active

ABB ACS530-01-106A-4, 55 kW, 106 A, 380-480 V 3-phase, Frame R5, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3ABD00039814-D — Power & Output
ParameterValue
Output power, normal duty55 kW
Output current, normal duty106 A
Output power, light overload55 kW
Output current, light overload100 A
Apparent power output73.0 kV·A
Efficiency class (IE)IE2
Standby power loss24 W
3ABD00039814-D — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3ABD00039814-D — Mechanical & Cooling
ParameterValue
Frame sizeR5
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule
3ABD00039814-D — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

Drive selection memo: 55 kW motor duty, Frame R5

The 3ABD00039814-D: The ABB ACS530-01-106A-4 is a 55 kW variable frequency drive in Frame R5, rated for 106 A continuous output current at 380-480 V 3-phase input. That 106 A figure is the normal-use rating — sized for a standard 55 kW induction motor on a pump or fan curve. Light-overload duty still delivers 100 A at 55 kW, so the headroom is there for constant-torque loads up to that same power, just with a tighter current margin. Apparent power output sits at 73.0 kV·A, which gives you a ballpark for transformer or generator sizing upstream. Standby loss is 24 W — not a panel-heating concern for a drive this size, but worth noting if the cabinet shares space with temperature-sensitive controls.

The 380-480 V 3-phase input covers 480 V grids. Frequency acceptance spans 47.5 to 63 Hz. Maximum ambient temperature is 40 °C. The IP20 enclosure is standard for panel mounting. Efficiency class is IE2. Frame R5 determines the mounting footprint and gland-plate layout.

Frequently asked questions

What is 3ABD00039814-D's listed frame size?

The frame size is R5. This determines the mounting footprint and gland-plate layout.

What is the standby loss for this drive?

Standby loss is 24 W, which is low enough that cabinet heating is not a concern for most installations.

What are the key output ratings for this drive?

Normal-use output is 55 kW at 106 A; light-overload output is 55 kW at 100 A. Apparent power output is 73.0 kV·A.

MPN