Skip to main content
ABB 3ABD00045151 — AC Drive (VFD) 480V

ABB 3ABD00045151 ACS380 drive, 3 kW, 7.2 A, Frame R1

MPN3ABD00045151
Active

ABB ACS380 series, LV AC machinery drive module, 3ABD00045151, Frame R1, 3 kW / 7.2 A normal use, 380-480 V 3-phase, IP20, IE2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3ABD00045151 — Power & Output
ParameterValue
Output power, normal duty3 kW
Output current, normal duty7.2 A
Output power, heavy duty2.2 kW
Output current, heavy duty5.6 A
Output power, light overload3 kW
Output current, light overload6.8 A
Efficiency class (IE)IE2
3ABD00045151 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3ABD00045151 — Mechanical & Cooling
ParameterValue
Frame sizeR1
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule

Product details

The 3ABD00045151: Normal-use (Pn) is 3 kW at 7.2 A — that's the continuous rating for a typical constant-torque fan or pump. Heavy-duty (PhD) drops to 2.2 kW / 5.6 A, which is the number to use for a conveyor or extruder with intermittent overloads. Light-overload (PlD) stays at 3 kW but current is 6.8 A, so you get a bit more headroom on current for short peaks. Pick the duty class that matches your actual load profile, not the motor nameplate.

Lifecycle status is Active — no end-of-life notice.

Frequently asked questions

What is the frame size of this drive?

Frame R1, the smallest in the ACS380 series.

What are the normal-use and heavy-duty power ratings?

Normal-use (Pn) is 3 kW at 7.2 A; heavy-duty (PhD) is 2.2 kW at 5.6 A.

What input voltage and frequency does it accept?

380-480 V three-phase, 47.5-63 Hz.

MPN