ABB 3ABD00045162 — AC Drive (VFD) 240V

ABB 3ABD00045162 ACS380 Drive, 3 kW, 12.2 A, Frame R2

MPN3ABD00045162
Active

ABB ACS380 series, LV AC machinery drive module, 3ABD00045162, 200-240 V 1-phase input, 3 kW / 12.2 A output, Frame Size R2, IP20, IE2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Electrical Output

3ABD00045162 — Electrical Output
ParameterValue
Output power, normal duty (Pn)3 kW
Output current, normal duty (In)12.2 A
Output power, heavy duty (PhD)2.2 kW
Output current, heavy duty (IhD)9.8 A
Output power, light-overload duty (PlD)3.0 kW
Output current, light-overload duty (IlD)11.6 A
Efficiency class (IE)IE2

Electrical Input

3ABD00045162 — Electrical Input
ParameterValue
Input voltage range200 ... 240 V
Number of phases1-phase
Frequency47.5 ... 63 Hz

Mechanical

3ABD00045162 — Mechanical
ParameterValue
Degree of protection (IP)IP20
Enclosure type (NEMA)Open Type
Frame sizeR2
Mounting typeModule

Product details

The ABB 3ABD00045162 is an ACS380-series LV AC machinery drive module, rated for 200-240 V single-phase input and delivering 3 kW normal-duty output at 12.2 A. Frame size R2 keeps it compact for panel integration, and the IP20 enclosure suits clean, indoor electrical rooms — not washdown environments.

The normal-duty rating (Pn 3 kW, In 12.2 A) is what you size for a constant-torque load like a conveyor or fan running continuously. If you're driving a pump or compressor that occasionally sees a heavy slug, the heavy-duty rating (PhD 2.2 kW, IhD 9.8 A) gives you the thermal headroom — that's the number to use for the BOM line if the motor nameplate is 2.2 kW and the cycle includes brief overloads.

Rated IE2 efficiency level means it meets the minimum efficiency standard for most industrial applications in regions that mandate the IE2 baseline.

Frequently asked questions

Where can I buy 3ABD00045162 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quotation.

What is 3ABD00045162's listed frame size?

Frame size R2 — that's the mechanical footprint for panel layout and mounting hole pattern.

What is the input frequency range for this drive?

47.5 to 63 Hz, which covers both 50 Hz and 60 Hz mains supplies without derating.

MPN
3ABD00045162