3ABD00045177 ACS380-040C-01A8-4+K454 Drive, 0.55 kW / 1.8 A

MPN3ABD00045177
Active

ABB ACS380-040C-01A8-4+K454 machinery drive module, 0.55 kW / 1.8 A normal-use, frame size R0, 380-480 V 3-phase, IP20, IE2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ABD00045177 — Power & Output
ParameterValue
Output power, normal duty0.55 kW
Output current, normal duty1.8 A
Output power, heavy duty0.37 kW
Output current, heavy duty1.2 A
Output power, light overload0.55 kW
Output current, light overload1.7 A
Efficiency class (IE)IE2
3ABD00045177 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3ABD00045177 — Mechanical & Cooling
ParameterValue
Frame sizeR0
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule

Product details

Drive module for the line-down call

The 3ABD00045177: Heavy-duty use derates to 0.37 kW / 1.2 A — that's the number to size against if the load profile includes frequent overloads or a conveyor start. Light-overload rating sits at 0.55 kW / 1.7 A, matching the normal-use power rating with slightly lower current headroom.

The normal-use output (1.8 A at 0.55 kW) is the go-to rating for a continuous-duty motor load — a standard 0.55 kW induction motor on a fan or pump. Heavy-duty (1.2 A at 0.37 kW) covers the same motor frame but with the extra thermal headroom for a high-inertia start or a cyclic overload profile.

R0 frame — compact, DIN-rail mountable, typical for a 0.55 kW drive. IP20 means no condensation or dust ingress protection; the drive needs a clean, dry enclosure. 380-480 V three-phase input; wire per the nameplate diagram. Motor cable screen should be bonded at the drive end per ABB's EMC guide.

Frequently asked questions

What is the difference between the normal-use and heavy-duty ratings?

Normal-use output is 0.55 kW / 1.8 A for continuous loads. Heavy-duty derates to 0.37 kW / 1.2 A for applications with frequent overloads or high-inertia starts. Light-overload rating is 0.55 kW / 1.7 A.

What IP rating and efficiency level does this drive have?

IP20 open type (panel-mount only) and IE2 efficiency level.