For constant-torque or high-starting-torque applications, the heavy-duty rating of 169 A (90 kW) applies — that is the number to use when sizing for conveyors or extruders. A light-overload rating is also listed at 196 A (110 kW), which sits between the two. The IE2 efficiency class means the drive meets the minimum efficiency level required in most industrial installations today.
Physical and environmental specs
The drive is housed in frame size R7 and is wall-mounted. The enclosure is NEMA Type 1 with an IP21 ingress protection rating — suitable for indoor installation where dripping water and limited dust ingress are not a concern. It falls under WEEE Category 4 (Large Equipment), which affects end-of-life handling in EU jurisdictions.