Skip to main content
ABB 3ABD00046041-D — AC Drives (VFD)

ABB 3ABD00046041-D ACQ580-01 Drive, 90 kW, 169 A, IP21

MPN3ABD00046041-D
Active

ABB, ACQ580-01 series, wall-mounted LV AC drive, 90 kW / 169 A normal use, 75 kW / 145 A heavy-duty, 380-500 V 3-phase, IP21, NEMA 1, Frame R7.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Electrical

3ABD00046041-D — Electrical
ParameterValue
Input voltage380 ... 500 V
Frequency47.5 ... 63 Hz
Number of phases3-phase

Power & Current

3ABD00046041-D — Power & Current
ParameterValue
Output power, normal duty90 kW
Output power, heavy duty75 kW
Output power, light-overload duty90 kW
Output current, heavy duty145 A
Output current, normal duty169 A
Output current, light-overload duty161 A
Efficiency class (IE)IE2

Protection & Environmental

3ABD00046041-D — Protection & Environmental
ParameterValue
Degree of protection (IP)IP21
NEMA enclosure typeType1

Mechanical

3ABD00046041-D — Mechanical
ParameterValue
Frame sizeR7
Mounting typeWall-mounted

Product details

Enclosure & mounting

Wall-mounted in a NEMA 1 (IP21) enclosure, frame size R7. IP21 means protected against solid objects over 12 mm and dripping water — fine for a dry pump room or treatment gallery, but not for washdown zones. NEMA 1 keeps the electronics behind a ventilated sheet-metal cover; no conduit knockouts are pre-punched for the R7 frame, so plan for gland-plate entry on-site.

Supply & frequency range

Input accepts 380-500 VAC at 47.5-63 Hz, covering 50 Hz and 60 Hz grids worldwide. The wide frequency tolerance means it handles weak generator supplies or off-nominal conditions on remote well sites without nuisance tripping.

Frequently asked questions

What is the frame size of 3ABD00046041-D?

Frame size R7. That's the physical mounting footprint for the wall-mounted enclosure, corresponding to the 169 A output current rating.

What input voltage and frequency does this drive accept?

380-500 V three-phase, 47.5-63 Hz. Works on both 50 Hz and 60 Hz supplies with no reconfiguration.

What is the difference between the normal-use and heavy-duty ratings?

Normal use is 90 kW / 169 A for centrifugal loads (pumps, fans). Heavy-duty is 75 kW / 145 A for constant-torque loads (screw pumps, conveyors, mixers). Use the heavy-duty figure when sizing for a load that demands full torque across the speed range.

Where can I buy 3ABD00046041-D and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution channels. Submit an RFQ for current pricing and availability — confirmed at quote time, not a published figure.

MPN
3ABD00046041-D