ABB 3ABD00046056-D — AC Drives (VFD)

ABB 3ABD00046056-D ACH580-01 Drive, 200 kW, 363 A, IP21, R9

MPN3ABD00046056-D
Active

ABB 3ABD00046056-D, ACH580-01 series, wall-mounted LV AC drive, 200 kW normal-duty, 363 A, 380-500 V, 3-phase, IP21, NEMA Type 1, IE2, frame R9.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Electrical

3ABD00046056-D — Electrical
ParameterValue
Input voltage380 ... 500 V
Frequency47.5 ... 63 Hz
Number of phases3-phase

Power & Current

3ABD00046056-D — Power & Current
ParameterValue
Output power, normal duty200 kW
Output power, heavy duty160 kW
Output power, light-overload duty200 kW
Output current, heavy duty293 A
Output current, normal duty363 A
Output current, light-overload duty345 A
Efficiency class (IE)IE2

Protection & Environmental

3ABD00046056-D — Protection & Environmental
ParameterValue
Degree of protection (IP)IP21
NEMA enclosure typeType1

Mechanical

3ABD00046056-D — Mechanical
ParameterValue
Frame sizeR9
Mounting typeWall-mounted

Product details

The ABB 3ABD00046056-D is an ACH580-01 wall-mounted drive sized for a 200 kW motor in normal-duty use, delivering 363 A continuous. It runs on a 380-500 V three-phase supply across 47.5-63 Hz, so it handles 50 Hz and 60 Hz plants without a re-rate. Frame R9 means this is a large unit; you're looking at a bolted wall mount, not a DIN rail clip. Heavy-duty use is rated at 160 kW / 293 A, and light-overload at 200 kW / 345 A — the normal-duty number is the one to spec for a constant-torque fan or pump, but the heavy-duty figure gives you headroom if the load spikes.

Enclosure & Environment

Wall-mount only; no floor-standing adapter in this order code. The IE2 efficiency class is standard for this generation of drives; it meets the basic EU and UK efficiency requirements for variable-speed operation.

WEEE Category 4 (Large Equipment) applies for end-of-life disposal planning in Europe — expect the crossed-out wheelie bin marking on the nameplate.

Frequently asked questions

What is the frame size and mounting type?

Frame size R9, wall-mounted only. This is a large drive — not a DIN-rail unit — so plan for a dedicated backplate or wall bracket with adequate clearance for the IP21 enclosure.

What are the key output ratings for normal, heavy-duty, and light-overload use?

Normal-duty: 200 kW / 363 A. Heavy-duty: 160 kW / 293 A. Light-overload: 200 kW / 345 A. The normal-duty figure is the one to use for constant-torque fan/pump applications; heavy-duty gives you margin for cyclic loads.

MPN
3ABD00046056-D