ABB 3ABD00046375 ACQ531 Drive, 1.1 kW, 3.3 A, Frame R0

MPN3ABD00046375
Active

ABB ACQ531-01-03A3-4, Frame R0, 1.1 kW, 3.3 A, 380-480 V 3-phase, IP20, Module.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ABD00046375 — Power & Output
ParameterValue
Output power, normal duty1.1 kW
Output current, normal duty3.3 A
Output power, light overload1.1 kW
Output current, light overload3.1 A
Apparent power output2.3 kV·A
Efficiency class (IE)IE2
Standby power loss15 W
3ABD00046375 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3ABD00046375 — Mechanical & Cooling
ParameterValue
Frame sizeR0
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule
3ABD00046375 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

The ABB 3ABD00046375 is an ACQ531-01-03A3-4 variable-frequency drive rated for 1.1 kW normal-use output at 3.3 A, with a light-overload rating of 1.1 kW at 3.1 A — identical power but slightly lower current, meaning the drive is sized for continuous duty at nameplate and the light-overload curve covers the same kW at a marginally reduced thermal load. It accepts 380 to 480 V three-phase input across 47.5 to 63 Hz, making it suitable for 50 Hz and 60 Hz mains without reconfiguration.

Efficiency and standby losses

Rated IE2 efficiency level, which meets the minimum efficiency standard for drives in most industrial applications. Standby loss is 15 W — low enough that leaving the drive powered for communication or pre-charge between shifts does not waste significant energy.

Mounts as a Module — typically on a DIN rail or a backplate inside a control panel. IP20 means no additional sealing is needed inside the enclosure, but the drive must be protected from washdown, dust, and condensation by the cabinet itself.

Frequently asked questions

What is the frame size of 3ABD00046375?

Frame R0, the smallest frame in the ACQ531 series. This determines the physical footprint and the mounting-hole pattern for panel installation.

What is the standby loss of this drive?

15 W. This is the power the drive consumes when the motor is not running but the control electronics remain powered.

Where can I buy 3ABD00046375?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN