3ABD00046377 — Power & Output
ParameterValue
Output power, normal duty2.2 kW
Output current, normal duty5.6 A
Output power, light overload2.2 kW
Output current, light overload5.3 A
Apparent power output3.9 kV·A
Efficiency class (IE)IE2
Standby power loss15 W
3ABD00046377 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3ABD00046377 — Mechanical & Cooling
ParameterValue
Frame sizeR0
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule
3ABD00046377 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

The 3ABD00046377: The ABB ACQ531-01-05A6-4 is a 3-phase drive rated for 2.2 kW normal-use output power at 5.6 A, with a light-overload rating of 2.2 kW at 5.3 A. Input voltage range is 380-480 V, 47.5-63 Hz, making it suitable for standard European and North American industrial supplies. The IE2 efficiency class means it meets the base efficiency level for variable-speed drives under the EU Ecodesign Directive — not the highest tier, but compliant for applications where premium efficiency isn't mandated. Rated apparent power output is 3.9 kV·A, which gives you the headroom calculation for transformer sizing or generator compatibility. Standby loss sits at 15 W — a figure to factor into enclosure cooling if the drive is idle for extended periods in a sealed panel.

Integration constraints

Frame size R0 is the smallest in the ACQ530 family, so panel space is tight — confirm DIN-rail or screw-mount footprint against your backplate layout before committing. IP20 and NEMA Open Type mean this drive is for indoor, clean-environment installation only; no washdown or dust protection. Ambient temperature max is 40 °C — derate output current if your enclosure runs hotter. Module mounting type suggests it's designed for direct panel mounting rather than a separate drive cabinet. The 15 W standby loss is low enough that forced ventilation may not be needed for a single unit, but group multiple drives and recalculate.

That means it's a safe line-item for BOM freeze without a near-term PCN watch.

Frequently asked questions

What is 3ABD00046377's listed frame size?

Frame size is R0, the smallest frame in the ACQ530 series. This determines mounting hole pattern and overall dimensions for panel layout.

What is the standby loss of this drive?

Standby loss is 15 W. This is the power dissipated when the drive is powered but not running a motor — relevant for enclosure thermal calculations.

Where can I buy 3ABD00046377?

This part is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — stock position and lead time are confirmed at quote time.