ABB 3ABD00046395 — AC Drive (VFD) 480V

ABB 3ABD00046395 ACQ531-01-363A-4 Drive, 200 kW, 363 A

MPN3ABD00046395
Active

ABB ACQ531-01-363A-4 drive, 200 kW, 363 A, 380-480 V, 3-phase, IP20, Frame Size R9.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ABD00046395 — Power & Output
ParameterValue
Output power, normal duty200 kW
Output current, normal duty363 A
Output power, light overload200 kW
Output current, light overload345 A
Apparent power output251.0 kV·A
Efficiency class (IE)IE2
Standby power loss80 W
3ABD00046395 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3ABD00046395 — Mechanical & Cooling
ParameterValue
Frame sizeR9
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule
3ABD00046395 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C

Product details

The 3ABD00046395: The 363 A normal-use output current (In) and 345 A light-overload current (IID) define the continuous and short-term overload headroom. At 200 kW both normal and light-overload power ratings are identical, which means the drive is sized for a steady 200 kW motor load without needing to derate for occasional overload cycles. The 251.0 kV·A apparent power output confirms the VA capacity for that power level at the rated voltage. Input voltage range is 380-480 V, 3-phase, 47.5-63 Hz. The IP20 enclosure suits panel-mount installations in a clean, dry electrical room. Frame size R9 tells you the mechanical footprint and mounting pattern. Standby loss of 80 W is the heat the drive dissipates when idle, which factors into panel cooling calculations — not a selection driver but relevant for thermal design in a sealed cabinet.

Frequently asked questions

What is 3ABD00046395's listed frame size?

The frame size is R9, which defines the mechanical footprint and mounting pattern for panel layout.

What is the standby loss of 3ABD00046395?

Standby loss is 80 W, which is the heat dissipated when the drive is idle — relevant for cabinet thermal design.

What are the key electrical ratings of 3ABD00046395?

It is rated for 200 kW normal-use output at 363 A, with a 380-480 V three-phase input, IE2 efficiency, and IP20 protection.

MPN
3ABD00046395