ABB 3ABD00046560-D — AC Drive (VFD) 480V

ABB 3ABD00046560-D ACS580-01 Drive, 30 kW, 62 A, IP21

MPN3ABD00046560-D
Active

ABB ACS580-01 general purpose wall-mounted drive, 30 kW / 62 A normal use, IP21, IE2, 380-480 V 3-phase.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ABD00046560-D — Power & Output
ParameterValue
Output power, normal duty30 kW
Output current, normal duty62 A
Output power, heavy duty22.0 kW
Output current, heavy duty45 A
Output power, light overload30 kW
Output current, light overload58 A
Efficiency class (IE)IE2
3ABD00046560-D — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3ABD00046560-D — Mechanical & Cooling
ParameterValue
Frame sizeR4
NEMA enclosure typeType1
Degree of protection (IP)IP21
Mounting typeWall-mounted

Product details

What this drive delivers

The ABB 3ABD00046560-D is an ACS580-01 general-purpose wall-mounted LV AC drive rated for 30 kW normal-use output at 62 A on a 380-480 V three-phase supply. It carries an IE2 efficiency class and IP21 protection, so it's suited for clean indoor environments where some splash resistance is needed but not full washdown. The drive also lists heavy-duty ratings of 22 kW / 45 A and light-overload ratings of 30 kW / 58 A, giving you a choice of how much headroom to budget for the application.

Sizing for the load profile

The normal-use rating (30 kW / 62 A) covers constant-torque loads like conveyors and positive-displacement pumps. For variable-torque loads such as centrifugal fans or pumps, the light-overload rating matches the same 30 kW output but at 58 A — slightly lower current because the torque demand drops with speed. Heavy-duty use (22 kW / 45 A) is the rating for high-starting-torque or shock-load applications like crushers or extruders. If your motor plate calls for 45 A or less and the duty cycle is demanding, the heavy-duty line is the one to spec against.

Frequently asked questions

What is the frame size of this drive?

The frame size is R4, which determines the physical mounting dimensions and panel cutout requirements.

What is the difference between the normal-use and heavy-duty ratings?

Normal use is 30 kW / 62 A for constant-torque loads. Heavy-duty use is 22 kW / 45 A for higher starting torque or shock loads. Choose the rating that matches your motor's full-load current and duty cycle.

MPN