Skip to main content
ABB 3ABD00046783-D — AC Drive (VFD) 480V

ABB 3ABD00046783-D ACS580-01-05A7-4+N7511+0J400+P944, 2.2 kW

MPN3ABD00046783-D
Active

ABB ACS580-01 wall-mounted general purpose drive, 380-480 V 3-phase, IP20, Frame R1, 2.2 kW / 5.6 A normal duty, IE2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Power & Output

3ABD00046783-D — Power & Output
ParameterValue
Output power, normal duty2.2 kW
Output current, normal duty5.6 A
Output power, heavy duty1.5 kW
Output current, heavy duty4.0 A
Output power, light overload2.2 kW
Output current, light overload5.3 A
Efficiency class (IE)IE2

Input / Supply

3ABD00046783-D — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz

Mechanical & Cooling

3ABD00046783-D — Mechanical & Cooling
ParameterValue
Frame sizeR1
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeWall-mounted

Product details

The ABB 3ABD00046783-D is an ACS580-01 wall-mounted general-purpose drive, 380-480 V three-phase input, rated 2.2 kW normal-use output at 5.6 A. Heavy-duty rating is 1.5 kW / 4.0 A, light-overload rating 2.2 kW / 5.3 A. Frame size R1, IP20 open-type enclosure. Frequency range 47.5 to 63 Hz covers 50/60 Hz grids. Efficiency class IE2.

The normal-use rating (2.2 kW, 5.6 A) is the continuous output for a typical 4-pole induction motor at 400 V. The heavy-duty rating (1.5 kW, 4.0 A) applies when the drive must handle higher overload — e.g., a crusher or a centrifuge with a 150% peak for 60 seconds. The light-overload rating (2.2 kW, 5.3 A) is for constant-torque loads like conveyors that don't need the extra headroom. The 380-480 V input range covers European 400 V and North American 480 V three-phase, 50 or 60 Hz.

Frequently asked questions

What is the frame size and enclosure type?

Frame size R1, wall-mounted, IP20 open-type enclosure.

What are the key output ratings?

Normal use: 2.2 kW / 5.6 A. Heavy duty: 1.5 kW / 4.0 A. Light overload: 2.2 kW / 5.3 A.

What input voltage and frequency does it accept?

380-480 V three-phase, 47.5-63 Hz.

MPN
3ABD00046783-D