Skip to main content
ABB 3ABD00046785-D — AC Drive (VFD) 480V

ABB 3ABD00046785-D ACS580-01-09A5-4+N7511+0J400+P944, 4 kW,

MPN3ABD00046785-D
Active

ABB ACS580-01-09A5-4+N7511+0J400+P944, 3ABD00046785-D, general-purpose wall-mounted drive, 380-480 V, 4 kW normal use, 9.4 A output, IP20.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Power & Output

3ABD00046785-D — Power & Output
ParameterValue
Output power, normal duty4 kW
Output current, normal duty9.4 A
Output power, heavy duty3.0 kW
Output current, heavy duty7.2 A
Output power, light overload4.0 kW
Output current, light overload8.9 A
Efficiency class (IE)IE2

Input / Supply

3ABD00046785-D — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz

Mechanical & Cooling

3ABD00046785-D — Mechanical & Cooling
ParameterValue
Frame sizeR1
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeWall-mounted

Product details

The ABB 3ABD00046785-D is an ACS580-01 general-purpose wall-mounted drive rated for 4 kW normal-use output at 9.4 A on a 380-480 V three-phase supply. Heavy-duty duty drops to 3.0 kW at 7.2 A, so sizing for a constant-torque load like a conveyor or positive-displacement pump should use the heavy-duty column. Light-overload use (4.0 kW, 8.9 A) covers variable-torque fans and centrifugal pumps.

Mounting & wiring notes

Wall-mounted with IP20 protection — no gland plate seal, so run conduit or cable glands into the bottom entry. Frame R1 accepts up to 4 mm² power wiring; torque terminals to the values in the manual. The input frequency range of 47.5 to 63 Hz covers 50 Hz and 60 Hz grids without derating. Open-type NEMA enclosure means no drip-proof cover; install in a cabinet if washdown or dust is present.

Frequently asked questions

What are the key output ratings for this drive?

Normal-use output is 4 kW at 9.4 A; heavy-duty is 3.0 kW at 7.2 A; light-overload is 4.0 kW at 8.9 A. The input voltage range is 380-480 V three-phase.

What frame size is 3ABD00046785-D?

Frame size R1 — the smallest in the ACS580-01 line, suited for wall-mounting with a compact footprint.

MPN
3ABD00046785-D