ABB 3ABD00046788-D — AC Drive (VFD) 480V

3ABD00046788-D ACS580-01-026A-4, 11 kW, IP20, Frame R2

MPN3ABD00046788-D
Active

ABB ACS580-01-026A-4+N7511+0J400+P944, 11 kW general purpose LV AC drive, 380-480 V 3-phase, IP20, frame size R2, wall-mounted.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Power & Output

3ABD00046788-D — Power & Output
ParameterValue
Output power, normal duty11 kW
Output current, normal duty25 A
Output power, heavy duty7.5 kW
Output current, heavy duty17.0 A
Output power, light overload11.0 kW
Output current, light overload23.8 A
Efficiency class (IE)IE2

Input / Supply

3ABD00046788-D — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz

Mechanical & Cooling

3ABD00046788-D — Mechanical & Cooling
ParameterValue
Frame sizeR2
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeWall-mounted

Product details

Drive selection memo — 11 kW normal duty, frame R2

The 3ABD00046788-D: IP20 enclosure suits clean indoor environments; the open-type NEMA rating matches. IE2 efficiency level is standard for this generation of drives.

Heavy-duty use at 7.5 kW and 17.0 A gives headroom for constant-torque applications like extruders or crushers that demand sustained peak current. Light-overload rating at 11.0 kW and 23.8 A fills the gap for cyclic loads with moderate overload profiles. Frame R2 determines the mounting hole pattern and gland plate layout. Wall-mount installation is standard; verify the gland plate accommodates the incoming cable diameter for the 25 A rating.

Frequently asked questions

What is the frame size of this drive?

Frame size R2. This determines the physical mounting dimensions and gland plate layout for wall-mount installation.

What are the key power ratings?

Normal use: 11 kW at 25 A. Heavy-duty use: 7.5 kW at 17.0 A. Light-overload use: 11.0 kW at 23.8 A. Input voltage is 380-480 V three-phase at 47.5-63 Hz.