Duty ratings
The 3ABD00046800-D: Normal-use output is 160 kW / 293 A. Heavy-duty use drops to 132 kW / 246 A, and light-overload use holds 160 kW / 278 A. The heavy-duty figure governs continuous motor load on a 4-pole induction machine; the light-overload rating applies when the load profile stays below the drive's thermal limit for extended periods.
Product status is active.